REMOTE CONTROL COMMAND PROTOCOL
18 / 32
38. AGC Level Setting
; Set the AGC Level of the camera according to the data of “AGC_CTL” .
0xC5
0xAA
0x7D
AGC_CTL
CAM_ID
C·S
2) Camera -> PC
0xC5
0xAA
C·S
0x7D
AGC_CTL
0x7D
0xXX
0xXX
0xXX
1) PC -> Camera
AGC_CTL ; This is a data for which adjusts a AGC level of the camera.
Data value range :: 00d(Minimum AGC Level) ~ 255d(Maximum AGC Level)
39. Function OSD Display Mode Change
; Change the Function OSD Display Mode of the camera according to the data of “OSD_CNT” .
0xC5
0xAA
0x64
OSD_CNT
CAM_ID
C·S
2) Camera -> PC
0xC5
0xAA
C·S
0x64
OSD_CNT
0x64
0xXX
0xXX
0xXX
1) PC -> Camera
OSD_CNT ; In case of OSD_CNT = 0x00, The Function OSD Display Mode is changed to “Whole Function
OSD OFF” mode.
In case of OSD_CNT = 0x01, The Function OSD Display Mode is changed to “Bottom line
Function OSD Only OFF” mode.
In case of OSD_CNT = 0x02, The Function OSD Display Mode is changed to “Bottom line
Function OSD Only ON” mode.
In case of OSD_CNT = 0x03, The Function OSD Display Mode is changed to “Whole Function
OSD ON” mode.
Otherwise, The Function OSD Display Mode is not changed.