LVC-A630’S Specifications
2. RELIABILITY TESTS
1) Normal Operation Test ( Initial Camera’s Performance Test )
23
˚
C
±
5
˚
C 60 % RH
* Check the Camera’s performance , and measurement data ( Compare with given tolerance limit ) .
2) Operating Conditions ( Temperature , Humidity )
0
˚
C
∼
40
˚
C 0 % RH
∼
60 % RH
3) Environmental Test Procedure ( With Camera only )
40
˚
C , 60 % RH 8 Hours
0
˚
C , 0 % RH 8 Hours
* Conditions : 1. Leave the camera unit at above condition ( High temperature & Low temperature ).
2. After this test , Check the camera’s performance and measurement data .
3. Compare the data with given specifications
4) Storage Test Conditions & Procedure ( With Carton )
60
˚
C , 85 % RH 48 Hours
-20
˚
C , 0 % RH 48 Hours
* Conditions : 1. Leave the carton at above condition ( High temperature & Low temperature ) .
2. After this test , moving it at normal temperature ( 23
˚
C ) for 10hours .
3. Check the camera’s performance and measurement data .
4. Compare the data with given specifications
5) Electrostatic Caution
* It will be damaged Camera module without outer case which flowed in the Electrostatic.
It is necessary to prepare Electrostatic ring , clothes , etc to prevent electrostatic.
6) Vibration Test ( With Carton )
* Vibrate the camera 4mm widths of a vibration ( 1000rpm , 17Hz ) .
Check the camera”s operations after testing each direction X,Y,Z for 30 minutes duration of
a vibration .
7) Drop Test ( WITH CARTON )
* Drop the camera under conditions of height 70 Cm , one corner , 3 edges , 6 surfaces .
Check the camera’s operations after testing for 1 time .
8) Regulations * CE Certification ( CLASS A)
Warning
This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
9) Durability
a) Zoom Motor ; More than 500,000 cycles at room temperature .
b) Focus Motor ; More than 1,000,000 cycles at room temperature .
c) Iris ; More than 500,000 cycles at room temperature .
3 / 9