REMOTE CONTROL COMMAND PROTOCOL
26 / 32
55. Read the current BRIGHTNESS data
; Read the current BRIGHTNESS data of the Camera.
The return data is “Brightness”.
0xC5
0xAA
0x89
0x00
CAM_ID
C·S
2) Camera -> PC
0xC5
0xAA
C·S
0x89
0x00
Brightness
0xXX
0xXX
0xXX
1) PC -> Camera
56. Read the current Shutter Speed Control counter value
; Read the current counter value to control Shutter Speed.
The return data is “SSC_CNT”.
0xC5
0xAA
0x8A
0x00
CAM_ID
C·S
2) Camera -> PC
0xC5
0xAA
C·S
0x8A
0x00
SSC_CNT
0xXX
0xXX
0xXX
1) PC -> Camera
57. Read the IRIS control data
; Read the current IRIS control value to control IRIS OPEN level.
The return data is “IRIS_CTL”.
0xC5
0xAA
0x8B
0x00
CAM_ID
C·S
2) Camera -> PC
0xC5
0xAA
C·S
0x8B
0x00
IRIS_CTL
0xXX
0xXX
0xXX
1) PC -> Camera
58. Read the AGC control data
; Read the current AGC control value to control AGC level.
The return data is “AGC_CTL”.
0xC5
0xAA
0x8C
0x00
CAM_ID
C·S
2) Camera -> PC
0xC5
0xAA
C·S
0x8C
0x00
AGC_CTL
0xXX
0xXX
0xXX
1) PC -> Camera