Installation in closed rooms - LW 225 E
For installation in closed rooms, observe the following:
• Install the unit horizontally and level. The floor must be vibration-free and capable of taking the
load of the system weight.
• The compressor room must be clean, dry, dust free and as cool as possible. Avoid direct exposure
to sunlight. If possible, install unit in such a manner that the compressor fan can intake fresh air
from outside. Ensure adequate ventilation and exhaust air opening.
• When locating the compressor in rooms of less than 30 m³ space where natural ventilation is not
ensured or other systems having high radiation are operating in the same room, measures must
be taken to provide artificial ventilation.
• Intake air must be free from noxious gas e.g. smoke, solvent vapours, exhaust fumes etc.
• Observe the specified operating temperature (see "Technical Data")!
Danger
No operation in explosion-hazard areas.
The unit is not approved for operation in areas prone to explosion.
!
I N S T A L L A T I O N
Summary of Contents for LW 225 E
Page 3: ...A Operating Instructions Breathing Air Compressor LW 225 E LW 245 B Version 02 14 E ...
Page 15: ...A S A F E T Y P R E C A U T I O N S ...
Page 22: ...A I N S TA L L AT I O N ...
Page 31: ...A O P E R AT I O N ...
Page 39: ...A R E M E D Y I N G FA U LT S ...
Page 44: ...A M A I N T E N A N C E A N D S E R V I C E ...
Page 73: ...A M A I N T E N A N C E R E C O R D S ...
Page 82: ...B ERSATZTEILLISTEN SPARE PARTS LISTS DETAILANSICHTEN DETAILED VIEWS ...
Page 111: ...C O P T I O N S Version 11 12 D ...
Page 113: ...C A U T O S H U T D O W N D 2 LW 225 E 245 B ...
Page 116: ...C A U T O M A T I C C O N D E N S AT I O N D R A I N D 5 LW 225 E 245 B ...
Page 118: ...C S W I T C H O V E R D E V I C E 2 0 0 3 0 0 B A R D 7 LW 225 E 245 B ...
Page 121: ...C A D D I T I O N A L F I L L I N G H O S E D 10 LW 225 E 245 B ...