Page A - 43
A
LW SC-300 E / LW SC-350 E
Version: 06.12.2022
M A I N T E N A N C E A N D S E R V I C E
Check V-belt tension
The V-belts could lose tension during transportation. Please check the V-belt tension before starting
the compressor.
Tension V-belts
To tighten V-belt tension, loosen 4 mounting nuts of the drive motor. Use the tensioning screw to
move the electric motor until the V-belt tension is sufficient. Then, tighten mounting nuts and check
V-belt tension.
We recommend using a V-belt tension gauge.
Correct V-belt tension
Do not tension V-belts too tight. This damages bearings of compressor and motor. The V-belts
should only be tensioned until there is no noise caused by slipping during start.
Motor Type
Initial Installation
Operation after running in
Electric motors 50Hz
500 N
400 N
Electric motors 60Hz
400 N
300 N
Settings
Summary of Contents for SC-300 E
Page 3: ...A Operating Instructions Breathing Air Compressor LW SC 300 E LW SC 350 E Version 12 22 E...
Page 12: ...A S A F E T Y P R E C A U T I O N S...
Page 19: ...A I N S TA L L AT I O N...
Page 26: ...A O P E R AT I O N...
Page 34: ...A R E M E D Y I N G FA U LT S...
Page 39: ...A M A I N T E N A N C E A N D S E R V I C E...
Page 67: ...A M A I N T E N A N C E R E C O R D S...
Page 75: ...E A T T A C H M E N T Version 11 12 E...
Page 79: ...INFORMATIONON THE SERVICE LIFE OF L W HIGH PRESSURE HOSES...
Page 87: ...ANNEX...