Page A - 47
A
LW SC-300 E / LW SC-350 E
Version: 06.12.2022
M A I N T E N A N C E A N D S E R V I C E
Final pressure switch
The pressure switch shuts off the compressor automatically
when the selected final pressure is reached. The final
pressure switch is already adjusted to the corresponding cut-
out pressure.
The pressure can be adjusted with the upper adjusting screw
as follows:
Increasing cut-out pressure:
Turn the adjusting screw clockwise
Reducing cut-out pressure:
Turn the adjusting screw anti-clockwise
Adjust the pressure switch in steps of a quarter turn. Restart the
compressor after every adjustment step to verify the actual cut-out pressure.
Example settings:
Note
Do not adjust the final pressure switch to the safety valve pressure. The final pressure switch
has to be adjusted to min. 10 bar below the safety valve pressure. Otherwise, the safety valve
can open during operation. This considerably reduces the life of the safety valve.
i
Final pressure switch
Safety valve
Max. Operating Pressure
225 bar
215 bar
250 bar
240 bar
330 bar
320 bar
Summary of Contents for SC-300 E
Page 3: ...A Operating Instructions Breathing Air Compressor LW SC 300 E LW SC 350 E Version 12 22 E...
Page 12: ...A S A F E T Y P R E C A U T I O N S...
Page 19: ...A I N S TA L L AT I O N...
Page 26: ...A O P E R AT I O N...
Page 34: ...A R E M E D Y I N G FA U LT S...
Page 39: ...A M A I N T E N A N C E A N D S E R V I C E...
Page 67: ...A M A I N T E N A N C E R E C O R D S...
Page 75: ...E A T T A C H M E N T Version 11 12 E...
Page 79: ...INFORMATIONON THE SERVICE LIFE OF L W HIGH PRESSURE HOSES...