LW SC-600 ES / LW SC-680 ES / LW SC-750 ES
Version: 01.01.2023
Page A - 22
A
I N S T A L L A T I O N
Electrical Installation
For installation of electrical equipment, observe the following:
• If control devices are delivered by the factory, refer to the appropriate wiring diagram.
• Ensure correct installation of protective conductors.
• Check conformity of motor and control device tension and frequency with those of the electric
network (see name plate on the compressor).
• The fusing should be done in accordance with the valid regulations of the responsible electricity
supply company.
• When connecting the unit to the electrical supply, check the compressor direction of rotation
(see chapter "Maintenance" -> Check turning direction).
• Fuse the motor correctly (see table; use slow-blow fuses).
Warning
Work on the electrical equipment on / with the machine / unit may only be carried out by
qualified electricians.
!
No.
Designation
1.
Circuit diagram number
2.
Compressor type
3.
Power supply
4.
Frequency
5.
Motor current consumption
6.
Nominal motor power
Fig. Compressor name plate
2.
1.
3.
4.
5.
6.
Summary of Contents for SC-600 ES
Page 3: ...A Operating Instructions Breathing Air Compressor LW SC 600 ES LW SC 680 ES LW SC 750 ES...
Page 12: ...A S A F E T Y P R E C A U T I O N S...
Page 19: ...A I N S TA L L AT I O N...
Page 26: ...A O P E R AT I O N...
Page 34: ...A R E M E D Y I N G FA U LT S...
Page 39: ...A M A I N T E N A N C E A N D S E R V I C E...
Page 67: ...A M A I N T E N A N C E R E C O R D S...
Page 75: ...C Version 20 11 2023 ERSATZTEILLISTEN SPARE PARTS LISTS DETAILANSICHTEN DETAILED VIEWS...
Page 132: ...E A T T A C H M E N T Version 11 12 E...
Page 136: ...INFORMATION ON THE SERVICE LIFE OF L W HIGH PRESSURE HOSES...
Page 144: ...ANNEX...