LW SC-600 ES / LW SC-680 ES / LW SC-750 ES
Version: 01.01.2023
Page A - 36
A
R E M E D Y I N G F A U L T S
Filter Life not Sufficient
Cause of fault
Remedy
Pressure maintaining valve settings not correct
Adjust as prescribed
Filter cartridge unsuitable
Replace by a prescribed filter cartridge type
Filter cartridge too old
Observe expiration date
Filter cartridge packaging incorrect / damaged /
already opened. Filter cartridge already partly
saturated before change
Store filter cartridges properly, dispose defective
cartridges
Cylinder(s), piston(s) or piston ring(s) defective
Replace
Operating temperature too high
Ensure sufficient ventilation
Oil Consumption too High
Cause of fault
Remedy
Cylinder(s), piston(s) or piston ring(s) defective
Replace
Compressor oil unsuitable
Use prescribed oil quality
Operating temperature too high
Observe prescribed operating temperatures
Oil leak at the compressor block
Tighten corresponding mounting screws, if
necessary replace corresponding paper sealing /
o-ring / shaft seal
Summary of Contents for SC-600 ES
Page 3: ...A Operating Instructions Breathing Air Compressor LW SC 600 ES LW SC 680 ES LW SC 750 ES...
Page 12: ...A S A F E T Y P R E C A U T I O N S...
Page 19: ...A I N S TA L L AT I O N...
Page 26: ...A O P E R AT I O N...
Page 34: ...A R E M E D Y I N G FA U LT S...
Page 39: ...A M A I N T E N A N C E A N D S E R V I C E...
Page 67: ...A M A I N T E N A N C E R E C O R D S...
Page 75: ...C Version 20 11 2023 ERSATZTEILLISTEN SPARE PARTS LISTS DETAILANSICHTEN DETAILED VIEWS...
Page 132: ...E A T T A C H M E N T Version 11 12 E...
Page 136: ...INFORMATION ON THE SERVICE LIFE OF L W HIGH PRESSURE HOSES...
Page 144: ...ANNEX...