background image

CAUTION

RISK OF ELECTRIC SHOCK DO NOT OPEN

SUPPLY VOLTAGE

HT FUSE

CAUTION

TO REDUCE THE RISK OF FIRE REPLACE 

ONLY WITH SAME TYPE AND RATING

MODEL : GH100TI
SERIAL NO.

1*16 OHM

MAXIMUM POWER CONSUMPTION

300 WATTS

CAUTION - TO REDUCE THE RISK OF 
ELECTRIC SHOCK, DO NOT REMOVE 
COVER. NO USER SERVICABLE PARTS 
INSIDE. REFER SERVICING TO 
QUALIFIED SERVICE PERSONEL.
WARNING - THIS APPARATUS MUST 
BE EARTHED
WARNING - TO REDUCE THE RISK OF 
FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS APPLIANCE TO 
RAIN OR MOISTURE.
ATTENTION REMPLACER LE FUSIBLE 
PR LE MEME ET CALIBRE
ATTENTION DEBRACHER A LA PRISE 
SECTEUR AVANT D’OUVRIR

Laney

T1A L

MAINS FUSE

~220-240V = T2A L 250V

~100-120V = T5A L 250V

1*8 OHM

1*4 OHM

2*16 OHM

2*8 OHM

LOUDSPEAKERS

WARNING:

USE ONLY ONE IMPEDANCE

SELECTION AT A TIME

5881/6L64

EL34

BYPASS

SIDE/

CHAIN

INSERT

SEND

RETURN

5

4

3

2

1

0

10

9

8

7

6

FX RETURN

LEVEL

SLAVE IN

SLAVE OUT

BIAS

Made in the UK

www.laney.co.uk

SLAVE

PO WE R  TO  TH E  MU SI C

Laney

                  OPERATING INSTRUCTIONS

GH100TI SAMPLE SYSTEM 

8 Ohms

Link

Model  

RB115

Power Rating

 

300W Program

Model  

RB115

Power Rating

 

300W Program

Serial Number:

Serial Number:

Input

Laney

Power To The Music

www.laney.co.uk

DESIGNED IN THE UK BY LANEY

16 Ohms

Link

Model  

RB115

Power Rating

 

300W Program

Model  

RB115

Power Rating

 

300W Program

Serial Number:

Serial Number:

Input

Laney

Power To The Music

www.laney.co.uk

DESIGNED IN THE UK BY LANEY

SAMPLE

GS412LA

Input

FX Controller

Page 13 /16

GS412LS 16 Ohm

GS412LA 16 Ohm

8 Ohms

Link

Model  

RB115

Power Rating

 

300W Program

Model  

RB115

Power Rating

 

300W Program

Serial Number:

Serial Number:

Input

Laney

Power To The Music

www.laney.co.uk

DESIGNED IN THE UK BY LANEY

16 Ohms

Link

Model  

RB115

Power Rating

 

300W Program

Model  

RB115

Power Rating

 

300W Program

Serial Number:

Serial Number:

Input

Laney

Power To The Music

www.laney.co.uk

DESIGNED IN THE UK BY LANEY

SAMPLE

GS412LS

Output

Connected to the single 
8 ohm socket. (Two 16ohm
cabinets in parallel = 8ohms)

Sidechain Mode

H

1

TI

G

00

Summary of Contents for GH100TI

Page 1: ...100W ALL TUBE GUITAR HEAD AMPLIFIER POWER TO THE MUSIC Laney GH1 T 00 IOPERATING INSTRUCTIONS 2 1 w w w l a n e y c o u k Tony Iommi Tony Iommi...

Page 2: ...king it readily operable 15 Metal parts can be cleaned with a damp cloth The vinyl covering used on some units can be cleaned with a damp cloth or ammonia based household cleaner if necessary Disconne...

Page 3: ...s de decharge electrique ou de feu n exposez pas cet appareil a la pluie ou a l humidite Avant d utiliser cet appareil lisez les advertissments supplentaires situes dans le guide VORSICHT VORSICHT ACH...

Page 4: ...eck the number with the explanations adjacent to each panel Your Laney amplifier has undergone a thorough two stage pre delivery inspection involving actual play testing When you first receive your La...

Page 5: ...nual and familiarise yourself with the controls as it will allow you to get the best from your amplifier We hope you enjoy using your GH100TI as much as we enjoyed designing and making it Best wishes...

Page 6: ...sound can become muddy at very high gain levels depending upon your choice of guitar BRIGHT Adds brightness and sparkle to the upper frequencies This control is more effective at lower gain settings G...

Page 7: ...still keep them warm This allows you to switch out of standby and play without waiting for your amplifier to warm up This is useful after you have sound checked and you are waiting to go on stage leav...

Page 8: ...fire hazard The mains fuse ratings are detailed in the specs section at the rear of this manual HT FUSE This fuse protects the DC power to the tubes within the amplifier USE ONLY THE CORRECT SIZE AND...

Page 9: ...level of FX return is controlled by the FX return level control This allows you to set the right mix between the dry signal and the effects signal When the Effects loop switch is in Side Chain mode t...

Page 10: ...3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8...

Page 11: ...2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6 5 4 3 2 1 0 10 9 8 7 6...

Page 12: ...hum and microphony The preamp tubes can safely be changed with no action required if they fail or reduce in performance Typical output tube problems can be blown HT fuse sound lacking in punch sound...

Page 13: ...Made in the UK www laney co uk SLAVE PO WE R TO TH E MU SI C Laney OPERATING INSTRUCTIONS GH100TI SAMPLE SYSTEM 8 Ohms Link Model RB115 Power Rating 300W Program Model RB115 Power Rating 300W Program...

Page 14: ...ls on your guitar amplifier and then turn off its power before turning off other equipment Cables never use shielded or microphone cable for any speaker connections as this will not be substantial eno...

Page 15: ...itch Presence Switchable Extra Drive Stage Input Impedance 1MOhm 47pF Size Unit Weight 23Kg Loudspeaker Outputs 1 16 Ohm 1 8 Ohm 2 16 Ohm 1 4 Ohm 2 8 Ohm H W D 260 675 250 This product conforms to the...

Page 16: ...oduct development Laney Reserves the right to amend product specification without prior notification POWER TO THE MUSIC Laney JAZZ AMPICONS ARE HERE TO HELP BLUES ROCK METAL w w w l a n e y c o u k LA...

Reviews: