background image

3

TABLE OF CONTENTS

Specifications  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4
Equipment Description   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   5 - 6
Unpacking .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  7
Installation

 

Leg Installation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  8

 

Ventilation & Clearence .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  9

 

Electrical Connection  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  9

 

Phasing  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  9

Initial Start-Up

 

Griddles, Seasoning .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 0

 

TH Hood .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 0

Operation

 

General  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

 

Loading the Griddle .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

 

Suggested Times and Temperatures  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

Maintenance

 

Daily Cleaning .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

 

Weekly Cleaning   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

 

Calibration .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

Troubleshooting

 

Symptoms / Possible Causes .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

 

Possible Causes / Test  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

Wiring Diagram

 

TH Hood 2M-64-W5  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5 

 

Griddle 2M-63-25  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

Exploded View & Parts List  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7 - 24

PROBLEMS, QUESTIONS or CONCERNS

Before you proceed consult you authorized Lang service agent directory

or

Call the Lang Technical Service & Parts Department at 314-678-6315.

NOTICE 

Service on this or any other Lang appliance must be performed by qualified 

personnel only. Consult your Lang Authorized Service Agent Directory.  
You can call our tech service number 314-678-6315 or visit our website  
www.langworld.com for the service agent nearest you.

Summary of Contents for 124TH

Page 1: ...IL1559 ELECTRIC GRIDDLE w 24 CLAMSHELL 124TH 136TH 136TH 136THR 148TH 148THR 148THS 148TH2 Installation and Operation Instructions 2M W351 Rev F 1 27 12 136TH...

Page 2: ...IZED SERVICE PERSONNEL ONLY NOTICE Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability Lang reserves the right to change specifications and product...

Page 3: ...s Possible Causes 14 Possible Causes Test 14 Wiring Diagram TH Hood 2M 61114 W51 15 Griddle 2M 61113 25 16 Exploded View Parts List 17 24 PROBLEMS QUESTIONS or CONCERNS Before you proceed consult you...

Page 4: ...ply 124TH 2 3VMG 220 380 60 3 12 27 27 27 10 5 23 10 124TH 208MGT 208V 60 1 3 12 58 4 50 29 29 6 6 29 10 124TH 208V 208V 60 1 3 12 58 4 50 29 29 6 6 29 10 124TH 208VMG 208V 60 1 3 12 58 4 50 29 29 6 6...

Page 5: ...s steel There is a 3 clearance between griddle and hood Controls Griddle Each twelve inch section has a manual thermostat with a temperature range of 175 F to 450 F in 50 increments The thermostat is...

Page 6: ...d loss or damage means it does not become apparent until the merchandise has been unpacked If concealed loss or damage is discovered upon unpacking make a written request for inspection by the carrier...

Page 7: ...he 5 8 bolt through the stand into griddle IL1562 Std Leg DANGER THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED FAILURE TO GROUND THE APPLIANCE COULD RESULT IN ELECTROCUTION AND DEATH INSTAL...

Page 8: ...is provided for service connections and can be accessed through a removable panel on the back of the griddle Use a supply wire suitable for at least 90 degree centigrade The griddle is shipped from t...

Page 9: ...ots that appear then wait two minutes and wipe off any excess oil Repeat these steps at 350 F 400 F and 450 F To dry out the Griddle set the thermostat to 250 F and turn on the power switch Allow the...

Page 10: ...h minimal loads do not load directly over the thermostat capillary tube as this will unnecessarily turn the burners on and overheat the remainder of the section not being utilized Turn the product and...

Page 11: ...my cake and then carbonize into a hard substance which is extremely difficult to remove To prevent this condition the following suggestions for cleanliness should be followed After each use scrape the...

Page 12: ...late for the first checkpoint This will check the center of the probe for the first cooking section Each checkpoint is located every 12 to the right from the last point and always 11 1 2 from the fron...

Page 13: ...TRIC POWER SUPPLY If an item on the list is followed by an asterisk the work should be done by a factory authorized service representative USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY LAN...

Page 14: ...0 10 10 10 11 11 12 12 13 13 GRIDDLE CONTACTOR BOX CLAMSHELL HOOD 26 CLAMSHELL FIELD WIRING NOTE 1 OR 3 PHASE L1 26 L2 27 A GRIDDLE FIELD WIRING NOTE SINGLE PHASE L1 1 3 L2 2 4 THREE PHASE L1 1 4 L2 2...

Page 15: ...10 JUMPER 10 SINGLE PHASE THREE PHASE SERVICE CONNECTION 1 MODEL L1 L2 SINGLE PHASE L3 L1 L2 208V ELEMENT HOOK UP L1 L2 2 240V 8 8 7 30 2 29 10 23 3 24 11 16 15 6 6 5 4 30 2 29 4 3 2 2 30 2 29 23 10 2...

Page 16: ...16 SK2399 Rev 10 06 08 1 32 2 3 4 5 6 7 8 9 14 10 17 15 16 18 19 20 21 10 24 23 25 26 27 10 33 10 10 29 DETAIL A 30 22 22 12 13 10 31 10 11 28 Model 124TH 136TH 148TH Electric Clamshell...

Page 17: ...R LOCK 10 INT STAR 124TH 14 2E 30500 07 1 TRM BLOCK 3PLELRGE 125AMP 124TH 15 2C 20103 01 4 SCRW SM PLT 10X7 8 PHIL 124TH 17 K9 XL 507 1 REAR COVER 124TH 18 2C 20104 04 4 SCRW PHD ST 8 32X 5 PLTD PHILP...

Page 18: ...14 2E 30500 07 1 TRM BLOCK 3PLELRGE 125AMP 136TH 15 2C 20103 01 4 SCRW SM PLT 10X7 8 PHIL 136TH 16 2E 30500 22 1 TRMINL STRP 8POLE 50A250V 136TH 17 K9 XL 507 1 REAR COVER 136TH 18 2C 20104 04 4 SCRW...

Page 19: ...22 1 TRMINL STRP 8POLE 50A250V 148TH 17 K9 XL 507 2 REAR COVER 148TH 18 2C 20104 04 4 SCRW PHD ST 8 32X 5 PLTD PHILP 148TH 19 2P 70903 02 2 PLG BTN PLTD MTL 1 2 148TH 2P 70903 06 1 PLG BTN PLTD MTL 1...

Page 20: ...Rev 10 06 08 DETAIL A Model 124TH 136TH 148TH Electric Clamshell 1 2 3 7 8 9 10 12 11 17 15 16 14 13 13 13 8 9 7 18 19 20 25 26 27 27 24 20 19 18 21 22 23 22 31 33 32 30 29 28 22 4 5 6 148THS SLIDE Se...

Page 21: ...SPLIT ALL 12 2C 20203 05 2 4 WASHER SS 3 8 USS FLAT ALL 13 2C 20301 08 4 8 NUT HEX 3 8 16 PLTD ALL 14 K9 XLH 237 1 2 DRIP SHIELD 124TH 136TH 148TH 14 K9 XLH 548 1 DRIP SHIELD ASSY 148THS 15 K9 XLH 265...

Page 22: ...22 SK2401 Rev 10 06 08 Model 148THS Electric Sliding Clamshell Frame Assy DETAIL B 1 5 6 7 8 7 5 3 8 8 3 11 9 10 5 17 3 3 7 8 9 8 12 13 14 15 15 2 3 4 9...

Page 23: ...SAE 148THS 4 2C 20104 12 2 SCRW HXHD CAP 5 16 18X2 148THS 5 K9 XLH 433 4 SLIDE BAR ANGLE SLIDER 148THS 6 K9 XLH 430 1 BAR SUPPORT LH SLIDER 148THS 7 2C 20104 10 8 SCRW HXHD CAP 5 16 18X3 4 148THS 8 2C...

Page 24: ...24 STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 678 6303 www star mfg com...

Reviews: