13
2M-W1823, Envirozone T
-Stat Electric Griddle
WARNING
CAUTION
TROUBLESHOOTING
Symptoms
What follows is a chart of Symptoms and Possible Causes to aid in diagnosing faults with the griddle.
Refer to the Symptoms column to locate the type of failure then to the Possible Cause for the items
to be checked.
To test for a possible causes refer to the TEST section and locate the Possible Cause then refer
to test to identify test procedures.
If an item on the list is followed by an asterisk (*), the work should be done by a factory authorized service
representative.
NOTICE:
Service on this, or any other, LANG appliance must be performed by qualified
personnel only. Consult your Lang Authorized Service Agent Directory or call
the factory at 314-678-6315, or www.langworld.com For the service agent
nearest you.
BOTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE THIS APPLIANCE
WHEN THE UNIT IS PLUGGED/WIRED INTO A LIVE RECEPTACLE. BEFORE
REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC
POWER SUPPLY.
USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED
BY LANG OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE BODILY
INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL
VOID ALL WARRANTIES.
SYMPTOM
POSSIBLE CAUSE
Whole Griddle will not heat
•
No Power to Griddle
One Section will not heat
•
Failed contactor
•
Failed Element.
Product Burning
•
Product left on griddle too long
•
Out of Calibration
Product Under cooked
•
Product removed too soon
•
Out of Calibration
POSSIBLE CAUSE
TEST
Product is cooked too long
•
No test available, operational condition
Failed Contactor
•
Remove the wires from the contactor coil and check for
continuity across the contactor coil connection*
•
Ensure the contactor moveable points move freely up
and down*
Failed Element
•
Confirm that Elements are getting correct voltage and
have continuity*