background image

PARTS LIST

 

       

February 11, 2015, Rev C

STAR INTERNATIONAL HOLDINGS INC. COMPANY

Star - Holman - Lang - Wells - Bloomfield - Toastmaster

10 Sunnen Drive, St. Louis, MO 63143 U.S.A.

(314) 678-6303

www.star-mfg.com

Model: 172ZT EnviroZone Electric Griddle

Fig No.

Part Number

Description

Quantity

Application

1

K9-142-201-363

GRIDDLE PLATE ASSY - 6’ ZTD

1

172ZTD

K9-142-201-63

GRIDDLE PLATE ASSY - 6’ZT

172ZT

K9-142-201-63-1

GRIDDLE PLATE ASSY - 6’ZT CHROME

172ZTC

K9-142-201-63-2

GRIDDLE PLATE ASSY 6’ ZT w/CSE12

172ZTHE

2

K9-XL-507-2

REAR COVER - ZT

2

172ZT

3

2C-20102-12

SCRW PHD ST 10-32X3/8

26

172ZT

4

2C-20102-21

SCRW PHD ST 10-32X1/2 PLT

12

172ZT

5

Y9-31200-02-1

GROUNDING LUG/+LABEL

4

172ZT

6

2E-30500-07

TRM BLOCK 3PLELRGE 125AMP

2

172ZT

7

2C-20103-01

SCRW SM PLT 10X7/8 PHIL

4

172ZT

8

2E-30500-22

TRMINL STRP 8POLE 50A250V

2

172ZT

9

2A-72500-20

LEG 10.25 WITH ADJ HEX

4

172ZT

10

K9-142-231-61

FRONT PANEL - MID ASSY - 6”

1

172ZT

K9-142-245

FRONT PANEL - RIGHT END

172ZT

K9-142-245-13

FRONT PANEL - ASY RIGHT END

172ZTHE

11

K9-141-251

GREASE DRAWER ASSY

2

172ZT

K9-142-251

172ZTD

12

K9-141-161-W1

GREASE DRAWER SLIDE WELD

2

172ZT

K9-142-161-W1

172ZTD

13

2R-W498-2

KNOB-RED, METAL INSERT .188

6

Mfg after 6-4-2013

2R-W498

KNOB-RED

Mfg before 6-3-2013

14

2M-W728-W4

LABEL - CONTROL 200-550F

6

172ZT

15

Y9-31601-01-1

PILOT LT 250V W/TIN CLIP

6

172ZT

Y9-31601-02-1

PILOT LT 480V W/TIN CLIP

172ZTD-480V

16

K9-60301-43-1

DIE CAST LOGO + TINNERMAN

1

172ZT

17

K9-142-241-1

FRONT PANEL ASSY-6’ LH

1

172ZT

18

2T-30402-07

STAT ADJ 550o 48 C/T

6

172ZT

19

K9-XL-532

BOLT AND SCREW ASSY

36

172ZT

20

K9-XL-434-1

ELEMENT PAN SPOTWELD

6

172ZT

K9-XL-434-2

ELEMENT PAN SPOTELED-30”D

172ZTD

21

K9-XL-424-1

ELEMENT PAN INSULATION

6

172ZT

K9-XL-424-2

ELEMENT PAN INSUL 30”DEEP

172ZTD

22

K9-XL-429

ELEMENT PLATE GUIDE WLDMT

6

172ZT

K9-XL-429-1

172ZTD

23

2N-11030-29

ELE GRD 208/240V4.5KW/6KW

6

172ZT

2N-11030-29-1

DUAL VOLTAGE ELEMENT-30”D

172ZTD

24

2N-11030-30

ELMNT GRID 208V 1257W

6

172ZT

2N-11030-30-1

PERIMETER ELEMENT-30”D

172ZTD

2N-11030-31-1

480V ELEMENT 30”

172ZTD-480V

25

K9-XL-505

BULB HOLDER ASSY - ELECT

6

172ZT

NI

2M-61114-W68

WD EZONE T’STAT GRIDDLE

AR

172ZT

NI

2P-50100-15

GRIDDLE SCRAPER 12”

1

CHROME UNITS

NI

2P-50100-16

BOM AMI CLEANER

1

CHROME UNITS

NI

2P-50100-17

20” PALMYRA BRUSH

1

CHROME UNITS

Summary of Contents for 124ZT

Page 1: ...IL2477a ENVIROZONE TSTAT ELECTRIC GRIDDLE Commercial 124ZT 136ZT 148ZT 160ZT 172ZT Installation and Operation Instructions 2M W1823 Rev C 2 11 2015 124ZT...

Page 2: ...OULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY NOTICE Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability Lang reserves the right to change spec...

Page 3: ...Crome Surface Griddle Care 12 Troubleshooting Symptoms Possible Causes 13 Possible Causes Test 13 Wiring Diagram 208 240VAC 14 480V 14 Exploded View Parts List 15 20 PROBLEMS QUESTIONS or CONCERNS Be...

Page 4: ...240 60 1 3 18 87 2 50 50 50 6 18 87 2 50 50 50 6 Model Dimensions Not including Legs Clearance from combustible surface Weight Freight Class Width Depth Height Actual Shipping 124ZT 24 61 cm 30 4 77...

Page 5: ...increments Each twelve inch section of the griddle is controlled by an area sensitive RTD probe which can sense and react to a temperature change of 4 F Each twelve inch section has a set of 6 K W ele...

Page 6: ...Prior to un crating move the griddle as near to its intended location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways a...

Page 7: ...CAUSE INJURY TO PERSONNEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is located on the right side of the griddle The grill voltage...

Page 8: ...n the 5 and 6 foot griddles Use a supply wire suitable for at least 90 C 194 F This griddle is shipped from the factory set up for a three phase service On 208V 220V 240V the wiring can be changed in...

Page 9: ...ter the griddle reaches 350 F 176 C for hour turn the griddle up another 50 F 10 C for another hour and repeat this until it is at 450 F 232 C for hour The unit may emit a small amount of smoke as the...

Page 10: ...duct is loaded to the side front or back of the temperature sensor the thermostat will react to the temperature change much slower During slow periods with minimal loads do not load directly over the...

Page 11: ...is an accumulation of burned on grease and food the griddle should be thoroughly scoured and re seasoned Use pumice or griddle stone while the griddle is warm Do not use steel wool because of the dan...

Page 12: ...llowed by wiping with clean wet cloth 3 Follow daily cleaning steps for Non Chrome Surfaces Note All Chrome griddles come with a scrapper p n 2P 50100 15 Bon Ami Cleaner p n 2P 50100 16 and a 20 Palmy...

Page 13: ...OTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE THIS APPLIANCE WHEN THE UNIT IS PLUGGED WIRED INTO A LIVE RECEPTACLE BEFORE REPLACING ANY PARTS DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY USE OF A...

Page 14: ...CK 5 PILOT LIGHT 6 5 L3 L2 L1 NOTES 160ZT 172ZT HAVE TWO POWER SUPPLY CONNECTIONS 160ZT CONN 1 USE 136ZT CONN 2 USE 124ZT 172ZT CONN 1 USE 136ZT CONN 2 USE 136ZT 2 3 2 3 2 3 2 3 4 1 1 1 1 148ZT 136ZT...

Page 15: ...5 2M W1823 Envirozone T Stat Electric Griddle SK2583 Rev A 6 28 13 Model Electric EnviroZone Griddle 124ZT thru 172ZT 1 2 3 4 7 8 9 11 12 10 27 28 29 26 15 13 14 15 16 17 19 20 21 22 23 24 25 18 5 4 6...

Page 16: ...8 2 KNOB RED METAL INSERT 188 2 Mfg after 6 4 2013 2R W498 KNOB RED Mfg before 6 3 2013 14 2M W728 W4 LABEL CONTROL 200 550F 2 124ZT 15 Y9 31601 01 1 PILOT LT 250V W TIN CLIP 2 124ZT Y9 31601 02 1 PIL...

Page 17: ...28 W4 LABEL CONTROL 200 550F 3 136ZT 15 Y9 31601 01 1 PILOT LT 250V W TIN CLIP 3 136ZT 4 136ZTHE Y9 31601 02 1 PILOT LT 480V W TIN CLIP 3 136ZT 480V 136ZTHE 380V 16 K9 60301 43 1 DIE CAST LOGO TINNERM...

Page 18: ...K9 142 251 148ZTD 12 K9 141 161 W1 GREASE DRAWER SLIDE WELD 2 148ZT K9 142 161 W1 148ZTD 13 2R W498 2 KNOB RED METAL INSERT 188 4 Mfg after 6 4 2013 2R W498 KNOB RED Mfg before 6 3 2013 14 2M W728 W4...

Page 19: ...41 161 W1 GREASE DRAWER SLIDE WELD 160ZT 13 2R W498 2 KNOB RED METAL INSERT 188 5 Mfg after 6 4 2013 2R W498 KNOB RED Mfg before 6 3 2013 14 2M W728 W4 LABEL CONTROL 200 550F 5 160ZT 15 Y9 31601 01 1...

Page 20: ...251 172ZTD 12 K9 141 161 W1 GREASE DRAWER SLIDE WELD 2 172ZT K9 142 161 W1 172ZTD 13 2R W498 2 KNOB RED METAL INSERT 188 6 Mfg after 6 4 2013 2R W498 KNOB RED Mfg before 6 3 2013 14 2M W728 W4 LABEL C...

Reviews: