background image

2

 

SAFETY SYMBOL

Model No.:

Serial No.:

Voltage:

1-Phase or 3 Phase:

Purchased From:

Location:

Purchase Date:

Installed Date:

These symbols are intended to alert the user to the presence of important operating 

and maintenance instructions in the manual accompanying the appliance.

FOR YOUR SAFTEY

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN 

THE VICINTIY OF THIS OR ANY OTHER APPLIANCE.

The installation of the Appliance must conform to the NATIONAL FUEL GAS CODE "ANSI Z223.1 - LATEST 

EDITION" AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN/CGA-B149.1 NATURAL 

GAS INSTALLATION CODE OR CAN/CGA-B149.2 PROPANE INSTALLATION CODE AND LOCAL CODES WHERE 

APPLICABLE.

POST IN PROMINENT LOCATION

INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS.  THIS INFORMATION 

SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER.  AS A MINIMUM, TURN 

OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR AUTHORIZED SERVICE AGENT.  

EVACUATE ALL PERSONNEL FROM THE AREA.

WARNING

IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN 

CAUSE PROPERTY DAMAGE, INJURY OR DEATH.  READ THE INSTALLATION, OPERATION 

& MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS 

EQUIPMENT. 

WARNING

RISK OF FIRE OR ELECTRIC SHOCK

DO NOT OPEN

WARNING, 

TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE 

CONTROL PANEL.  NO USER-SERVICABLE PARTS INSIDE.  

REPAIRS SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY.

NOTICE

Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability.
Lang  reserves  the  right  to  change  speci

 cations  and  product  design  without  notice.    Such 

revisions  do  not  entitle  the  buyer  to  corresponding  changes,  improvements,  additions  or 

replacements for previously purchased equipment.
Due  to  periodic  changes  in  designs,  methods,  procedures,  policies  and  regulations,  the 

specifications  contained  in  this  sheet  are  subject    to  change  without  notice.    While  Lang 

Manufacturing  exercises  good  faith  efforts  to  provide  information  that  is  accurate,  we  are 

not  responsible  for  errors  or  omissions  in  information  provided  or  conclusions  reached  as  a 

result of using the speci

 cations.  By using the information provided, the user assumes all risks in con-

nection with such use.

MAINTENANCE AND REPAIRS

Contact your local dealer for service or required maintenance.  Please record the model number, serial 

number, voltage and purchase & Installation Information in the area below and have it ready when you 

call to ensure a faster service. 

Summary of Contents for ACCU-TEMP

Page 1: ...IL2466 ACCU TEMP Spark Ignition GAS GRIDDLE Commercial 224T 236T 248T 260T 272T Installation and Operation Instructions 2M W358 Rev I 3 03 15 236T...

Page 2: ...ON MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT WARNING RISK OF FIRE OR ELECTRIC SHOCK DO NOT OPEN WARNING TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOT REMOVE CON...

Page 3: ...13 Burner Air Shutter Adjustment 13 Troubleshooting Symptoms Possible Causes 14 Possible Causes Test 15 Wiring Diagram 16 Exploded View Parts List 18 28 PROBLEMS QUESTIONS or CONCERNS Before you proc...

Page 4: ...Actual Shipping 224T 16 4 x 24 1 x 30 4 243 lbs 280 lbs 65 418mm x 613mm x 773mm 110 kg 127 kg 236T 16 4 x 36 1 x 30 4 368 lbs 420 lbs 418mm x 917mm x 773mm 167 kg 191 kg 248T 16 4 x 48 1 x 30 4 Sides...

Page 5: ...NAT X 5 WC 224T NATLR X 5 WC 224TR NAT X 5 WC 236TCHG NAT X 5 WC 81 000 BTU hr 236TC LPTE X 10 WC 236TC NAT X 5 WC 236TCHE NAT X 5 WC 236THE NAT X 5 WC 236THE NATCD X 5 WC 236THG LP X 10 WC 236THG NAT...

Page 6: ...twelve inch section of the griddle is controlled independently Technical Griddle operates on either Natural gas or Propane This must be specified when ordering It is shipped with a Power Cord and Plu...

Page 7: ...THE UNIT IS EXTREMELY HEAVY FOR SAFE HANDLING INSTALLER SHOULD OBTAIN HELP AS NEEDED OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT SUCH AS A FORKLIFT DOLLY OR PALLET JACK TO REMOVE THE UNIT FROM...

Page 8: ...ed in the manifold for connecting a manometer Correct manifold pressures are 5 inches water column for natural gas 10 inches water column for propane When replacing the plug in the manifold a pipe joi...

Page 9: ...the main toggle switch to STANDBY Seasoning the Griddle Plate non chrome only Set the temperature dials to 300 F 148 C Observe the burners through the opening at the top of the control panel When the...

Page 10: ...ND DRY IF SPILLS OCCUR CLEAN IMMEDIATELY TO AVOID THE DANGER OF SLIPS OR FALLS CAUTION SUGGESTED TIMES AND TEMPERATURES PRODUCTS TEMPERATURE F C TIME MIN HAMBURGER 350 F 176 C 2 patties per LB 6 to 8...

Page 11: ...ature SEQUENCE OF OPERATION Power On When the griddle is connected to 115 Volt power the spark module for each section starts sparking While they are sparking the solenoid valve for the pilot burners...

Page 12: ...that the chrome surface has been misused or abused or subjected to the following situations 1 Improperly installed 2 Incorrect voltage applied to Chrome units allowing the surface to overheat and dis...

Page 13: ...Y READ THE WARNING AND FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE USED NOTICE Never leave a chlorine sanitizer in contact with stainless steel surfaces longer than 10 minutes Longer conta...

Page 14: ...test to identify test procedures SYMPTON POSSIBLE CAUSE Entire griddle not lighting Failed regulator or plugged regulator vent Failed transformer Power indicator is not lit No power to cord outlet Gr...

Page 15: ...AN CAUSE BODILY INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES CAUTION WARNING POSSIBLE CAUSE TEST Failed regulator Replace regulator Failed thermostat Check for corre...

Page 16: ...L D D I R G S A G 6 3 P M E T U C C A D W 7 0 0 2 9 1 2 1 4 3 W 2 2 1 1 6 M 2 5 1 0 x x x D E T O N S S E L N U E C N A R E L O T S E L G N A 1 L T N I G F M R A T S O T L A I T N E D I F N O C N O I...

Page 17: ...OCK PAIR REQUIRED FOR NOTES 1 2 3 4 4 7 5 5 7 8 8 10 11 9 4 7 5 8 DJS 10 23 2007 W D ACCUTEMP 3 GAS GRIDDLE WITH CSE12 CLAMSHELL 2M 61122 W24 CK 1 2 3 UP DOWN C B A R W BLU W 9 3 5 6 4 16 15 10 10 10...

Page 18: ...Rev A 7 19 13 Model 224T thru 272T GAS ACCU TEMP GRIDDLE 1 3 2 4 5 6 7 8 9 10 11 13 15 14 16 17 18 23 29 Correctional Package 24 25 28 26 27 19 21 22 20 12 Electrical Conduit Units mfg before July 20...

Page 19: ...43 1 SWITCH GUARD 17 2I 05 07 0013 1 BOOT SWITCH 18 Y9 31601 07 1 1 PILOT LT 28V W TIN CLIP 19 2C 20101 77 4 SCRW MS PLT 6 32 X 25 20 Y9 70701 19 Black Y9 70701 19 2 Red 2 KNOB PLATE ASSY 450 D 21 2R...

Page 20: ...03 2 SHIELDMNT EZG STD W XLH12 FRONT GUTTER K9 EZGR 371 SHIELD MOUNT EZGR REAR GUTTER 12 K9 EZG 625 2 S S SIDE 13 2A Z0314 4 FOOT 4 DIE CAST 14 2T 30402 27 3 STAT ADJ 450 DEG 48 PILOT 15 2E 30303 06...

Page 21: ...1 13 2 SHIELDEND EZG STD W XLH12 11 K9 EZG 371 03 2 SHIELDMNT EZG STD W XLH12 12 K9 EZG 625 2 S S SIDE 13 2A Z0314 4 FOOT 4 DIE CAST 14 2T 30402 27 4 STAT ADJ 450 DEG 48 PILOT 15 2E 30303 06 1 SWT TOG...

Page 22: ...11 K9 EZG 371 03 2 SHIELDMNT EZG STD W XLH12 12 K9 EZG 625 2 S S SIDE 13 2A Z0314 4 FOOT 4 DIE CAST 14 2T 30402 27 5 STAT ADJ 450 DEG 48 PILOT 15 2E 30303 06 1 SWT TOG ON ON DPDT BLK 16 Z1 70 07 0343...

Page 23: ...DMNT EZG STD W XLH12 12 K9 EZG 625 2 S S SIDE 13 2A Z0314 6 FOOT 4 DIE CAST 14 2T 30402 27 6 STAT ADJ 450 DEG 48 PILOT 15 2E 30303 06 1 SWT TOG ON ON DPDT BLK 16 Z1 70 07 0343 1 SWITCH GUARD 17 2I 05...

Page 24: ...LOT TUBE 9 4 2K 70101 07 BRAS TBE TEE 1 4CC 5 2C 20102 04 SCRW PHD ST 8 32X 5 PLTD 6 2E 31400 07 XFORMR120 208 240 24V40VA 7 2J 80300 03 SPRK IGNITR MODULE SM2 9 2E 30501 03 TERM STRP 4 POLE W PUSH 10...

Page 25: ...PT 10 2K 70101 124 FITTING 1 8NPT X 3 8COMP 11 2V 6671 VALVE LINCOLN BRASS 3817 12 2C 20102 08 SCRW PHD ST 8 32X 375 13 K9 EZG W297 BRKT SOLENOID VALVE 14 2C 20102 04 SCRW PHD ST 8 32X 5 PLTD 15 PS 60...

Page 26: ......

Page 27: ......

Page 28: ...STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 678 6303 www star mfg com...

Reviews: