UL File# E8138 Rev New
10
INSTALLATION CONT’D
Ventilation and Clearances
Standard minimum clearance from combustible construction is as follows.
4” from side
4” from back
6” from floor
These ranges may be set directly, without legs, on a curbed base or
non-combustible
floor.
If the range is set without legs on a
non-combustible
floor or a curbed base, maintain
a 4-inch back clearance.
If the range is set directly against a
non-combustible
back wall, maintain a 6-inch
clearance to the floor.
Do not
install the oven closer than 4 inches from another range on the right hand side
(control panel side).
Do not
install the range closer than 12 inches from an uncontrolled heat source
(char-broiler, oven, etc.) on the right side.
CAUTION
ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM
COMBUSTIBLE MATERIALS AND DO NOT OBSTRUCT FLOW OF
COMBUSTION OR VENTILATION AIR.