8
INSTALLATION
DANGER:
THIS APPLIANCE MUST BE GROUNDED AT THE
TERMINAL PROVIDED. FAILURE TO GROUND THE
APPLIANCE COULD RESULT IN ELECTROCUTION AND
DEATH.
WARNING:
INSTALLATION OF THE UNIT MUST BE DONE BY
PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY.
IMPROPER INSTALLATION CAN CAUSE INJURY TO
PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT
MUST BE INSTALLED IN ACCORDANCE WITH ALL
APPLICABLE CODES.
NOTICE:
The data plate is located on top of the control box. The
griddle voltage, wattage, serial number, wire size, and
clearance specifications are on the data plate. This
information should be carefully read and understood
before proceeding with the installation.
NOTICE:
The installation of any components such as a vent hood,
grease extractors, fire extinguisher systems, must
conform to their applicable National, State and locally
recognized installation standards
.
Installing Griddle into Cabinet
Turn the griddle over, taking care not to kink the thermostat capillary tubes.
Set the griddle on the table that it is to be installed in (leaving a hole big enough to
slip the control panel through).
Insert the control panel through the hole and out the control opening of the cabinet.
The hole must be a minimum of 12” from the griddle and such that the control box
can come out of the cabinet 18” for serviceability.
Lower the griddle plate to sit flat in the table opening.
ELECTRICAL CONNECTION
The electrical connection must be made in accordance with local codes or in the
absence of local codes with
NFPA No. 70
latest edition (in Canada use
: CSA
STD. C22.1
).
A power connection box is provided for power connection.
This box must be installed a minimum of 18 inches away from the heating elements
in the cabinet box.
All electrical connections can be made at this box.
The range can now be connected to power.
CAUTION:
BE SURE THE POWER SUPPLY VOLTAGE MATCHES THE
VOLTAGE SPECIFIED ON THE NAMEPLATE LOCATED
ON THE TOP OF THE CONTROL BOX
12”
Summary of Contents for DI-60