12
2M-W1992: Electric Enviro-Zone Selectronic Griddle
TROUBLESHOOTING
Symptoms
What follows is a chart of symptoms and possible causes to aid in diagnosing faults with the griddle.
Refer to the Symptoms column to locate the type of failure then to the possible cause for the items
to be checked.
To test for a possible causes refer to the TEST section and locate the possible cause then refer
to test to identify test procedures.
SYMPTOM
POSSIBLE CAUSE
Whole Griddle will not heat
•
No Power to Griddle
•
Failed Power switch
•
Failed Transformer.
One Section will not heat
•
Failed Power switch (for that section)
•
Failed Probe
•
Failed Circuit board
•
Failed 12-position switch
•
Failed contactor
•
Failed Element.
Product Burning
•
Product left on griddle too long
•
Failed Probe
•
Failed Circuit board
•
Failed 12-position switch
Product Under cooked
•
Product removed too soon
•
Failed Probe
•
Failed Circuit board
•
Failed 12-position switch
Summary of Contents for EnviroZone 124ZD