2M-W1992: Electric Enviro-Zone Selectronic Griddle

DR

:

CK.

DA

TE

:

2M-61

114-W71

W/D - EZONE SELECTRONIC ELECTRIC GRIDDLES

3/4/14

ADAMS

LANG MANUF

ACTURING

# 10 SUNNEN DRIVE

ST

. LOUIS, MO. 63143, USA

THIS DRA

WING CONT

AINS INFORMA

TION CONFIDENTIAL

 T

O ST

AR MFG. INT'L

INC. NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED

TOLERANCE: UNLESS NOTED:  .xxx ± .015

ANG

LES

±

 1

°

REVISIONS

PAR

T NO.

MODEL

 NO.

TITLE

MA

TERIAL

FINISH

REV

.

DA

TE/ECO

DESCRIPTION OF CHANGE

DR

NOTES:

160ZS & 172ZS HA

VE 

TWO POWER SUPPL

Y CONNECTIONS

160ZT

: CONN #1 (RIGHT

 SIDE OF GRIDDLE) USE 124ZS

            CONN #2 (CENTER OF GRIDDLE) USE 136ZS

172ZT

: CONN #1 USE 136ZT

            CONN #2 USE 136ZT

4

5

148ZS

136ZS

124ZS

L3
L2
L1

GRIDDLE ELEMENTS

1

2

3

4

PILOT

 LIGHT

CONT

ACT

OR

JUMPER TERMINAL

 BLOCK

TERMINAL

 BLOCK

5

6

ELEMENT

 HOOKUP

208V

240V

INST

ALL

JUMPER (ITEM 4)

REMOVE JUMPER (ITEM 4)

MODEL

VOL

TAGE

KW

AMP

 T

OT

ALS - 3 PHASE

AMPS - 1 PHASE

SER

VICE CONNECTIONS THREE PHASE

SER

VICE CONNECTIONS SINGLE PHASE

L1-L2

L2-L3

L1-L3

TOT

AL

L1

L2

L3

L1

L2

L3

L1

L2

124ZS

208V

6.0

6.0

12.0

50.0

28.9

28.9

57.7

1,4

2

3

1,3

2,4

240V

6.0

6.0

12.0

43.3

25.0

25.0

50

136ZS

208V

6.0

6.0

6.0

18.0

50.0

50.0

50.0

86.5

1,4

2,5

3,6

1,3,5

2,4,6

240V

6.0

6.0

6.0

18.0

43.3

43.3

43.3

75

148ZS

208V

12.0

6.0

6.0

24.0

76.3

76.3

50.0

115.4

1,4,7

2,5,8

3,6

1,3,5,7

2,4,6,8

240V

12.0

6.0

6.0

24.0

66.1

66.1

43.3

100

3

5

4

1

2

7

8

3

2

JUMPER

7

8

TEMP

 CONTROL

 BOARD

12 POSITION SWITCH

R

TD TEMP

 PROBE

TRANSFORMER, CLASS 2

1

6

9

TOGGLE SWITCH

10

11

10

4

4

4

3

2

1

3

2

1

9

3

2

7

8

1

2

9

11

5

6

3

4

1

2

TRANSFORMER POWER WILL

 AL

W

AYS 

COME

FROM 

THE F

AR RIGHT

CONT

ACT

OR 

IN THE

GRIDDLE

9

10

8

7


5

6


3

6

6

6

3

5

4

1

2

9

7

8

9

10

8

7


5

6


3

3

5

4

1

2

9

7

8

9

10

8

7


5

6


3

3

5

4

1

2

9

7

8

9

10

8

7


5

6


3

Summary of Contents for EnviroZone 124ZD

Page 1: ...IL2799 ENVIROZONE SELECTRONIC ELECTRIC GRIDDLE Commercial 124ZS D 136ZS D 148ZS D 160ZS D 172ZS D Installation and Operation Instructions 2M W1992 Rev B 03 2018 136ZS...

Page 2: ...SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY NOTICE Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability Lang reserves the right to change s...

Page 3: ...shooting Symptoms Possible Causes 12 Possible Causes Test 13 Wiring Diagram 14 Exploded View Parts List 15 20 PROBLEMS QUESTIONS or CONCERNS Before you proceed consult you authorized Lang service agen...

Page 4: ...x 28 2 724 lbs 800 lbs 381mm x 1830mm x 717mm 329 kg 364 kg EQUIPMENT SPECIFICATIONS EQUIPMENT SPECIFICATIONS Model Volts AC Hz Ph Kw TOT Amp 1PH Supply Wire 1 PH Amp 3 Ph Supply Wire 3 PH Kw TOT Amp...

Page 5: ...period and limitations defined in this warranty will at Lang s discretion have the parts replaced or repaired by Lang or a Lang authorized service agency THIS WARRANTY IS SUBJECT TO ALL LISTED CONDITI...

Page 6: ...ts intended location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways Un crating The griddle will arrive co...

Page 7: ...OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is located behind access panel between controls and grease drawer The grill voltage wattage...

Page 8: ...e 208 240 griddle is a dual voltage design Jumper wires on terminal strip next to the main power supply connection determine the griddle voltage For a 208 volt power supply leave the jumpers in place...

Page 9: ...C for another hour and repeat this until it is at 450 F 232 C for hour The unit may emit a small amount of smoke as the cooking surface passes the 300 F 148 C point Do not be alarmed as the smoke is c...

Page 10: ...ct is loaded to the side front or back of the temperature sensor the thermostat will react to the temperature change much slower During slow periods with minimal loads do not load directly over the th...

Page 11: ...surface sparkling clean and performing at top efficiency DO NOT allow grease to accumulate as it will carbonize and become difficult to remove To prevent this condition the following cleaning suggesti...

Page 12: ...locate the possible cause then refer to test to identify test procedures SYMPTOM POSSIBLE CAUSE Whole Griddle will not heat No Power to Griddle Failed Power switch Failed Transformer One Section will...

Page 13: ...F ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY LANG OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE BODILY INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES POSSIBLE CAU...

Page 14: ...OOKUP 208V 240V INSTALL JUMPER ITEM 4 REMOVE JUMPER ITEM 4 MODEL VOLTAGE KW AMP TOTALS 3 PHASE AMPS 1 PHASE SERVICE CONNECTIONS THREE PHASE SERVICE CONNECTIONS SINGLE PHASE L1 L2 L2 L3 L1 L3 TOTAL L1...

Page 15: ...15...

Page 16: ...ric Enviro Zone Selectronic Griddle 1 2 4 5 6 7 9 11 12 13 14 18 23 25 26 27 29 28 11 31 30 10 32 33 34 35 10 24 10 19 20 21 22 15 17 16 10 8 10 3 SK2763 Rev 3 10 14 Model 136ZS Electric EnviroZone Se...

Page 17: ...9 142 441 2 RTD PROBE HOLDER 10 2C 20102 12 22 SCRW PHD ST 10 32X3 8 11 2C 20301 11 14 NUT HEX 8 32 PLTD 12 2E 30701 04 2 CONTC 2POLE 30A 24VAC 13 K9 142 152 W41 2 CONTACTOR BRACKET 14 2E 40101 W19 2...

Page 18: ...RTD PROBE HOLDER 10 2C 20102 12 25 SCRW PHD ST 10 32X3 8 11 2C 20301 11 14 NUT HEX 8 32 PLTD 12 2E 30701 04 3 CONTC 2POLE 30A 24VAC 13 K9 142 152 W41 3 CONTACTOR BRACKET 14 2E 40101 W19 3 CIRBD SI TE...

Page 19: ...3 8 11 2C 20301 11 18 NUT HEX 8 32 PLTD 12 2E 30701 04 3 CONTC 2POLE 30A 24VAC 13 K9 142 152 W41 4 CONTACTOR BRACKET 14 2E 40101 W19 4 CIRBD SI TEMP CONTROL 15 2K 70801 07 12 SPACER SUPPORT 1 2LG 16 2...

Page 20: ...0 2C 20102 12 42 SCRW PHD ST 10 32X3 8 11 2C 20301 11 24 NUT HEX 8 32 PLTD 12 2E 30701 04 5 CONTC 2POLE 30A 24VAC 13 K9 142 152 W41 5 CONTACTOR BRACKET 14 2E 40101 W19 5 CIRBD SI TEMP CONTROL 15 2K 70...

Page 21: ...301 11 28 NUT HEX 8 32 PLTD 12 2E 30701 04 6 CONTC 2POLE 30A 24VAC 13 K9 142 152 W41 6 CONTACTOR BRACKET 14 2E 40101 W19 6 CIRBD SI TEMP CONTROL 15 2K 70801 07 18 SPACER SUPPORT 1 2LG 16 2E 30304 22 6...

Page 22: ...STAR INTERNATIONAL HOLDINGS INC COMPANY Star Lang Wells Toastmaster 265 Hobson Street Smithville Tennessee 37166 U S A 314 678 6303 www langworld com www star mfg com...

Reviews: