11
Figure 1
SAFETY THERMOSTAT
The safety thermostat is located on the left end of the griddle behind control panel.
Remove the grease drawer.
Open the drop down door and remove four screws from the corners of the control panel.
Tip the control panel down on its hinges to access the thermostat.
The capillary tube is installed with the griddle thermostat capillary tube for section number one.
COMBUSTION BLOWER
The combustion blower is located on the bottom of the right broiler stanchion as viewed from the rear of
the griddle.
Figure 2
ACCESS TO GRIDDLE CONTROL COMPONENTS
All of the griddle control components are located behind the griddle control panel.
Remove the grease drawer.
Open the drop down door and remove four screws from the corners of the control panel.
Tip the control panel down on its hinges to access the controls.
Summary of Contents for GGB-24
Page 18: ...15 WIRING DIAGRAM ...