1
INSTALLATION
RECEIVING THE GRIDDLE
Upon receipt, check for freight damage, both visible and concealed. Visible damage should be noted on the
freight bill at the time of delivery and signed by the driver. Concealed loss or damage means loss or
damage which does not become apparent until the merchandise has been unpacked. If concealed loss or
damage is discovered, make a written request for inspection by the carrier's agent within 15 days of
delivery. All packing material should be kept for inspection.
Do not return damaged merchandise to
Lang Manufacturing Company. File your claim with the carrier.
Uncrate the appliance as near its intended location as practical. The crating will help protect the unit from
the physical damage normally associated with moving it through hallways and doorways.
DATA PLATE
A data plate is located on the left end of the griddle, just behind and over the top of the control panel.
The appliance’s voltage, wattage, gas type, gas pressure and clearances are located on this plate.
This information should be carefully read and understood before proceeding with the installation.
VENTILATION AND CLEARANCES
T
his appliance must be installed under a ventilation hood. The installation of any components such as vent
hoods, grease extractors, or fire extinguisher systems, must conform to their applicable nationally
recognized installation standards.
Minimum clearances from
combustible
materials shall be:
6 inches from side walls
14 inches from back wall
Minimum clearance from
any
surface shall be:
4 inches from bottom
Keep the appliance area free and clear of combustible material and do not obstruct the flow of combustion
or ventilation air.