8
FLO
W
BACK OF
UNIT
IL1828a
DRIP LEG*
GAS
SHUT-OFF
VALVE*
SUPPLIED
REGULATOR
* by others
GAS
SUPPLY*
VENT
GENERAL INSTALLATION DATA (continued)
GAS PIPING
Gas piping shall be of such size and so installed as to provide a supply of gas sufficient
to meet the full gas input of the appliance. If the appliance is to be connected to existing
piping, it shall be checked to determine if it has adequate capacity. Joint compound shall be
used sparingly and only on the male threads of the pipe joints. Such compounds shall be
resistant to the action of L.P. gases.
WARNING:
Any loose dirt or metal particles which are allowed to enter the gas lines on this
appliance will damage the valve and affect its operation. When installing this appliance, all
pipe and fittings must be free from all internal loose dirt.
GAS PRESSURE REGULATOR
A convertible pressure regulator is
provided with each range. It should
be connected to the inlet pipe at the
rear of the unit. The gas supply is then
connected to it. The supply pressure
to the regulator is not to exceed 1/2
PSIG. The water column manifold
pressure for 5" with natural gas & 10"
for LP gas.
Correct manifold pressures are:
5 inches water column for natural gas
10 inches water column for propane
MANUAL SHUT OFF VALVE
A manual shut off valve should be installed upstream from the manifold and within six feet of
the range.
CONNECTING GAS SUPPLY LINE
The gas inlet of the range is sealed at the factory to prevent entry of dirt. Do not remove this
seal until the actual connection is made to the gas supply line.
CHECKING FOR GAS LEAKS
Check entire piping system for leaks. Soap and water solution or other material acceptable
for the purpose, shall be used in locating gas leakage.
Matches, candle flame or other sources of ignition shall not be used
for locating gas leaks.
CAUTION
2M-W1662 Operation Manual - Lang Gas Countertop Range, GHP
Series
2M-W1662 Operation Manual - Lang Gas Countertop Range, GHP
Series