TESTS
Possible Cause
TEST
Blown fuses
•
No test available, replace fuses
Failed or tripped internal
breaker
•
Reset breaker
Failed thermostat
•
Verify calibration
•
Replace if necessary*
Failed Contactor
•
Verify that coil has correct voltage*
•
Verify that coil has continuity*
•
Verify that contactor points move
Failed 3-heat switch
•
Call factory or consult Service manual for
correct checks on each switch*
Failed element
•
Remove the wires and check for continuity
across the element*
Defective motor
•
Verify that motor wheel spins freely
•
Verify that motor has correct voltage*
Product is not baking properly
•
Verify thermostat calibration.
*
A factory authorized service representative should perform this work.