background image

 

Safety 

 

THE GRIDDLE IS EXTREMELY HEAVY. FOR SAFE 
HANDLING, INSTALLER SHOULD OBTAIN HELP AS 
NEEDED, OR EMPLOY APPROPRIATE MATERIALS 
HANDLING EQUIPMENT (SUCH AS A FORKLIFT, 
DOLLY, OR PALLET JACK) TO REMOVE THE UNIT 
FROM THE SKID AND MOVE IT TO THE PLACE OF 
INSTALLATION.

 

CAUTION

 

ANY STAND, COUNTER OR OTHER DEVICE ON 
WHICH GRIDDLE WILL BE LOCATED MUST BE 
DESIGNED TO SUPPORT THE WEIGHT OF THE 
GRIDDLE. 

 

SHIPPING STRAPS ARE UNDER TENSION AND CAN 
SNAP BACK WHEN CUT. 

DANGER:

 

THIS APPLIANCE MUST BE GROUNDED AT THE 
TERMINAL PROVIDED. FAILURE TO GROUND THE 
APPLIANCE COULD RESULT IN ELECTROCUTION 
AND DEATH. 

WARNING

 

INSTALLATION OF THE UNIT MUST BE DONE BY 
PERSONNEL QUALIFIED TO WORK WITH 
ELECTRICITY.  IMPROPER INSTALLATION CAN 
CAUSE INJURY TO PERSONNEL AND/OR DAMAGE 
TO EQUIPMENT.  UNIT MUST BE INSTALLED IN 
ACCORDANCE WITH ALL APPLICABLE CODES. 

NOTICE 

The data plate is on top of the control box. The 
griddle voltage, wattage, serial number, wire size, 
and clearance specifications are on the data plate.  
This information should be carefully read and 
understood before proceeding with the installation. 

NOTICE

 

The installation of any components such as a vent 
hood, grease extractors, fire extinguisher systems, 
must conform to their applicable National, State and 
locally recognized installation standards. 

NOTICE

 

During the first few hours of operation, you may 
notice a small amount of smoke coming off the unit, 
and a faint odor from the smoke.  This is normal for a 
new griddle and will disappear after the first few 
hours of use. 

CAUTION

 

ALWAYS KEEP THE AREA NEAR THE APPLIANCE 
FREE FROM COMBUSTIBLE MATERIALS. 

CAUTION

 

KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN 
AND DRY.  IF SPILLS OCCUR, CLEAN IMMEDIATELY, 
TO AVOID THE DANGER OF SLIPS OR FALLS. 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

Summary of Contents for R30S

Page 1: ...rive St Louis MO 63143 3800 Part Number 2M W1098 Ph 314 678 6315 Fax 314 781 2714 Rev A www langworld com March 7 2014 Installation Operation and Maintenance Instructions Electric Range Models R30S RI...

Page 2: ...UIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is on top of the control box The griddle voltage wattage serial number wire size and clearance specificatio...

Page 3: ...erformed by qualified personnel only Consult your Lang Authorized Service Agent Directory You can call our toll free number 314 678 6315 or visit our website www langworld com for the service agent ne...

Page 4: ...G WEIGHT MODEL NO 3PH LOADING TOTAL kW NORMAL AMPS PER LINE THREE PHASE SINGLE PHASE 208V 240V 480V 208V 240V L1 L2 L2 L3 L3 L1 L1 L2 L3 L1 L2 L3 L1 L2 L3 R30S RI30S 5 0 5 0 4 0 14 0 37 5 41 7 37 5 32...

Page 5: ...provisions do not cover abuse of this nature INITIAL START UP Hot Plates To dry out the hot plate set the thermostat dial at 250 F and turn on the power switch Allow unit to cycle at least 15 minutes...

Page 6: ...after the pan is removed Induction module controlled by variable heat control Great for rapid heat up it will generally boil water heat sauces or soups in about half the time of a French Plate Use cau...

Page 7: ...independently regulated for proper ratio of top and bottom heat to suit the product being baked or roasted by means of two 3 heat switches located in the panel at the right of the range The range ove...

Page 8: ...e range is 0 800 F 18 C 427 C Recommended Light duty saucepans and small stockpots Not Recommended heavy stockpots heavy urns or kettles 12 x 24 or 24 x 24 grill plates controlled by thermostats Tempe...

Page 9: ......

Page 10: ...ECTION AND THE OVEN ARE SHOWN AT LEFT CONNECTED TO THEIR RESPECTIVE CIRCUIT BREAKERS 3 SEE SERVICE CONNECTION CHART FOR PROPER CONNECTION OF CIRCUIT BREAKERS TO POWER SUPPLY 2 1 3 4 P1 P2 2 1 3 4 P1 P...

Page 11: ...MODEL RTI30 Induction Rangetop SK2613 Rev 7 23 12 3 4 5 2 6 7 14 15 21 13 12 11 10 9 8 16 17 18 19 20 1...

Page 12: ...TOR 3 8 10 2C 1492 16 SCREW 8 32X1 4 RHP STL NP 12 2C 20102 03 20 SCRW HXHD ST 8 32X3 8 SLT 13 P9 RF21 731 2 BOTTOM COVER INDUCTION 13 P9 RF21 732 2 INDUCTION LOWER DUCT 14 2C 20102 04 4 SCRW PHD ST 8...

Page 13: ...SK2355 Rev 3 6 07 Model R30S Marine Range Top Assy 1 2 3 7 3 8 9 10 14 16 17 18 11 12 6 4 5 Old Style See Control Panel Detail 4 5 18 Suggested Parts Stocking...

Page 14: ...LMNT TK 380V 2000W ATA 380V 6 P9 50300 82 2 1 EGOPLTE FRMEASY PHANT 32 ATB 2 ATA 7 P9 CR30 258 1 DRAWER COVER ALL 8 P9 50302 20 1 GRAB BAR ASSY CR30 M ALL 2C 20111 01 4 SCRW HXHD CAP 1 4 20X1 2 GRAB B...

Page 15: ...SK2356 Rev 3 6 07 Model R30S Marine Range Oven Assy 1 3 4 6 7 10 9 8 12 15 15 24 22 23 15 15 13 13 14 14 16 17 18 19 20 21 11 5 2 Suggested Parts Stocking 11 13 14 22 7 8 9 10 4...

Page 16: ...440V 480V 8 2T 30402 08 1 STAT ADJ 450o 72 C T ALL 9 2E 30304 35 2 SWTROT3HT 240 480VAC20AMP ALL 10 Y9 70701 16 1 KNOB ASSY 450 F BLACK Y9 70701 16 2 1 KNOB ASSY 450 F RED 11 Y9 70701 10 2 KNOB 3 HEA...

Page 17: ...20109 04 6 SCREW THD MS SS 10 32X 3 8 A C B Part No Qty Description 50302 302 1 SEARAILASSY 2 RT30 32 SK A 50302 307 1 SEARAIL LH SIDE RT30 B 50302 308 1 SEARAIL RH SIDE RT30 C 50302 317 6 SEARAIL SI...

Page 18: ...9 R30S ATB 1 2 4 10 8 9 16 16 8 13 14 13 7 6 R30S ATC 2 4 8 15 16 8 10 10 12 14 13 7 6 R30S ATD 2 4 16 16 8 11 14 15 9 13 13 7 6 SK2357 Rev 3 7 08 Model R30S Marine Range Top Controls 10 6 11 13 14 Su...

Page 19: ...R30S ATE 2 4 3 7 8 8 12 15 15 11 10 14 16 13 14 16 13 6 R30S ATF 3 4 7 12 13 14 16 16 8 15 8 11 15 14 6 10 6 11 13 14 Suggested Parts Stocking SK2358 Rev 3 7 08 Model R30S Marine Range Top Controls...

Page 20: ...2T 30402 08 1 STAT ADJ 450o 72 C T ATD ATE 2T 30402 08 2 STAT ADJ 450o 72 C T ATF 12 P9 CR30 311 1 CONTROL FRONT SS ATA P9 CR30 312 1 CONTROL FRONT HS GS ATB ATD P9 CR30 313 1 CONTROL FRONT HH ATC ATE...