background image

Model No: R60S-ATA, R60S-ATB, R60S-ATC, R60S-ATD, R60S-ATE, R60S-ATF, R60S-ATG, R60S-ATH 

COMMERCIAL & MARINE ELECTRIC 60” RANGE

PARTS LIST

  

 

 

 

 

 

 

May 30, 2013, Rev B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    

   

 IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED 

PAGE 

1

 INCLUDE MODEL AND SERIAL NUMBER 

OF 

5

Some items are included for illustrative purposes only and in certain instances may not be available.

Fig No

Part Number

Qty

Description

Application

1

P9-50302-297

1

SEARAIL ASSY 1’(RF&500)

R60S-ATEM, -ATF-M

P9-50302-298

SEARAIL ASSY 2’ (RF&500)

R60S-ATD-M, -ATI-M

P9-50302-300

SEARAIL ASSY 5’ {500}

R60S-ATA-M, -ATB-M

P9-50302-301

SEARAIL ASSY 3’ (RF&500)

R60S-ATC-M

2

P9-50401-02

1

RANGE PLATE ASSY 1/2 X 2’

R60S-ATC

P9-50401-03

RANGE PLATE ASSY 1/2 X 3’

R60S-ATD, -ATI

P9-50401-10-1

RANGE PLATE ASSY 1” X 3’

R60S-ATI1

P9-50401-11-1

RANGE PLATE ASSY 1’ X 4’

R60S-ATE-M, -ATF-M

P9-50401-12-1

RANGE PLATE MODULE 1 X 5’

R60S-ATG

3

GROOVING

GRIDDLE GROOVING

4

P9-50300-82-1

1

EGO PLAT FRM ASY PHANT

R60S-ATB, -ATC, -ATD, -ATF

5

EGO PLAT FRM ASY PHANT

R60S-ATH

5

2N-11120-12

2

ELMNT TK 208V 2600W

R60S-ATB-208/208M, -ATC-208, -ATD-208, -ATF-208

4

R60S-ATI-208

10

R60S-ATH-208

2N-11120-13

2

ELMNT TK 240V 2600W

R60S-ATB-240/240M, -ATC-240/240M, -ATD-240, -ATF-240

10

R60S-ATH-240

2N-11120-14

2

ELMNT TK 480V 2600W

R60S-ATB-480M, -ATC-480/440M/480M, -ATD-480/440M/480M, -ATF-

480/480M

4

R60S-ATI440M, R60-ATI-480/M

6

R60S-ATJ-480

10

R60S-ATH-480

2N-11120-18

2

ELMNT TK 380V 2000W

R60S-ATB380M, R60-ATC380M R60S-ATD380M

6

PS-11010-371

1

HOTPLATE 400V 500W CAST

R60S-ATD380M

2

R60S-ATC380M

4

R60S-ATB380M

PS-11010-341

1

ASY, HOTPLATE 208V 5000W

R60S-ATD-208

2

R60S-ATC-208

4

R60S-ATB-208

5

R60S-ATA-208

PS-11010-351

2

ASY, HOTPLATE 240V 5000W

R60S-ATC-240V

4

R60S-ATB-240, -ATB240M

5

R60S-ATA-240

PS-11010-361

1

ASY, HOTPLATE 480V 5000W

R60S-ATD440M/480M

2

R60S-ATC-480/440M/480M

4

R60S-ATB480M

5

R60S-ATA440M, -ATA-480M R60S-ATA-480V

1

Summary of Contents for R60S-ATA

Page 1: ...D BAKE OVEN RANGE Commercial Marine R60S ATA R60S ATB R60S ATC R60S ATD R60S ATE R60S ATF R60S ATG R60S ATH R60S ATI R60S ATJ Installation and Operation Instructions 2M W822 Rev C 10 4 12 R60S ATA480M...

Page 2: ...N MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT WARNING RISK OF FIRE OR ELECTRIC SHOCK DO NOT OPEN WARNING TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOT REMOVE CONT...

Page 3: ...heck 7 Calibration Adjustment 7 Troubleshooting 8 Wiring Diagram 9 Exploded View Parts List 11 17 PROBLEMS QUESTIONS or CONCERNS Before you proceed consult you authorized Lang service agent directory...

Page 4: ...ght Class not including legs Actual Shipping R60S 32 x 60 x 35 2 Sides 4 100mm 685 1090 lbs 735 1140 lbs 85 813mm x 1524mm x 894mm Back 4 100mm 310 494 kg 333 517 kg R60S Marine 40 9 x 60 37 8 Sides 4...

Page 5: ...TE IL2011 G 60 x 34 GRIDDLE FRENCH PLATE FRENCH PLATE FRENCH PLATE FRENCH PLATE FRENCH PLATE FRENCH PLATE FRENCH PLATE FRENCH PLATE FRENCH PLATE FRENCH PLATE IL2011 H 36 x 34 GRIDDLE FRENCH PLATE FREN...

Page 6: ...a skid Remove the cardboard cover cut the straps and remove the wood frame RANGE WEIGHS AROUND 900 LBS 408 kilograms FOR SAFE HANDLING INSTALLER SHOULD OBTAIN HELP AS NEEDED OR EMPLOY APPROPRIATE MAT...

Page 7: ...nts such as a vent hood grease extractors fire extinguisher systems must conform to their applicable National State and locally recognized installation standards Electrical Connection All connections...

Page 8: ...griddle to 350 F 176 C and repeat the procedure NOTICE During the first few hours of operation you may notice a small amount of smoke coming off the unit and a faint odor from the smoke This is norma...

Page 9: ...tch Temperature ranges from 0 F 750 F Recommended Light duty sauce pans and small stockpots Not Recommended Heavy stock pots or heavy urns or kettles 60 x 24 or 48 x 24 or 36 x 24 or 24 x 24 grill pla...

Page 10: ...dirt is allowed to accumulate on it Take advantage of the clean sanitary features of electric equipment Give it the regular attention that it deserves the same as any other highly perfected machinery...

Page 11: ...o long Operational condition Product is not cooked Failed thermostat Verify calibration Failed 3 heat switch Call factory or consult service manual for correct checks on each switch NOTICE Service on...

Page 12: ...Wiring Diagram...

Page 13: ......

Page 14: ...A 10 05 2010 MODEL R60S Electric 60 Range 26 23 25 24 38 46 39 40 37 44 36 45 1 13 14 16 17 21 20 19 15 35 18 12 3 2 5 4 6 7 8 9 10 11 28 27 29 22 41 42 46 43 34 33 34 32 31 30 OVEN CONTROLS RANGE CO...

Page 15: ...12 1 RANGE PLATE MODULE 1 X 5 R60S ATG 3 GROOVING GRIDDLE GROOVING 4 P9 50300 82 1 1 EGO PLAT FRM ASY PHANT R60S ATB ATC ATD ATF 5 EGO PLAT FRM ASY PHANT R60S ATH 5 2N 11120 12 2 ELMNT TK 208V 2600W...

Page 16: ...N 11010 26 2 ELMNT T P 380V 1 S 3KW R60S ATC380M 3 R60S ATD380M 2N 11050 34 4 ELE 360VN 380V 1 S 1 2KW R60S ATB380M 8 2N 11010 09 2 ELMNT T P 208V 3KW O S R60S ATC 208V 3 R60S ATD 208V ATI 208 4 R60S...

Page 17: ...6 ELE 36OVN 240V I S 1 2KW R60S ATA 240V 17 2N 11050 25 4 ELE 36OVN 240V O S 1 8KW 240V 2N 11050 29 ELMNT 36OVEN 480V 9 C C R60S ATA440M 480M 480V ATB 480M ATC 480 440M 480M ATD1480M ATF 480 480M ATJ...

Page 18: ...S ATC ATD ATE ATF ATG ATI 4 R60S ATE ATF 5 R60S ATG Y9 70701 17 BLK Y9 70701 17 2 RED 2 KNOB ASSY 450 B R60S ATC 208V 34 Y9 31601 01 1 2 PILOT LT 250V W TIN CLIP R60S ATH 208 240 4 R60S ATD 208 240 6...

Page 19: ...DOOR FRAME ASSY R60S ATA 208 ATC 208 40 P9 500 310 2 1 BREAKER COVER HINGE 208 240V 41 2C 20201 13 2 WSHR BRASS 8 FLAT SAE R60S ATA440M 42 2P 51001 19 1 SPRING SWT DR HINGE EHS 440M 480 480M 2 208 208...

Page 20: ...STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 678 6303 www star mfg com...

Reviews: