DANGER:
THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL
PROVIDED. FAILURE TO GROUND THE APPLIANCE COULD RESULT IN
ELECTROCUTION AND DEATH.
WARNING:
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED
TO WORK WITH ELECTRICITY. IMPROPER INSTALLATION CAN CAUSE
INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT MUST
BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES.
NOTICE:
The data plate is located right of range top controls and behind the circuit
breaker door on oven. The oven voltage, wattage, serial number, wire size,
and clearance specifications are on the data plate. This information should
be carefully read and understood before proceeding with the installation.
NOTICE:
The installation of any components such as a vent hood, grease extractors,
fire extinguisher systems, must conform to their applicable National, State
and locally recognized installation standards.
Electrical Connection
All connections can be made through 1 3/4” hole in the bottom of the oven.
Connections should be made to the wires coming form the circuit breaker.
WARNING:
MAKE SURE THE MAIN POWER SUPPLY TO THE RANGE IS TURNED OFF
AT THE SOURCE PRIOR TO CONNECTING POWER TO THE RANGE.
The range can now be connected to power.
CAUTION:
BE SURE THE POWER SUPPLY VOLTAGE MATCHES THE VOLTAGE
SPECIFIED ON THE NAMEPLATE LOCATED ON THE FRONT OF THE
RANGE.
Total kW
Connection
Three Phase
Single Phase
208V
240V
480V
208V
240V
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
37.0
108.0
100.0
100.0
93.9
86.7
86.7
46.9
43.3
43.3
177.9
154.2
Power
Supply
Terminal
Block
Range
Top
Single Phase
L1
1,3,5,7,9,
L2
2,4,6,8,10
Three Phase
L1
1,4,7,10
L2
2,5,8
L3
3,6,9
4
Installation