7
2M-W1091, Commerical & Marine Electric Range T
op
2M-W1091, Commerical & Marine Electric Range T
op
INSTALLATION continued
Electrical Connection
The following table and illustrations provide the voltage and kilowatts necessary to operate the range
and oven
INITIAL START-UP
Hot Plates
To “dry out” the hot plate, set the thermostat dial at 250°F and turn on the power switch. Allow unit
to cycle at least 15 minutes at this heat level. Reset the thermostat to 350°F allowing the same time.
Then reset the thermostat to 450°F allowing the same time. Continue doing this until you reach
850°F then allow the unit to maintain this temperature for a minimum of 4 hours. More time may be
required if the unit has to operate in a moist environment.
If the unit is out of use for three or more days, a one-hour preheat schedule should be used,
especially when exposed to high humidity and/or cool temperatures.
French Plates
To “dry out” the Frenchplate, set the six-heat switch to the first setting and turn on the power switch.
Allow unit to cycle at least 15 minutes at this heat level. Reset the six-heat switch to position 2 and
allow the same time. Reset the six-heat switch to position 3 and allow the same time. Continue
doing this until you reach position 6 then allow the unit to maintain the temperature for a minimum of
4 hours. More time may be required if the unit has to operate in a moist environment.
If the unit is out of use for three or more days, a one-hour preheat schedule should be used,
especially when exposed to high humidity and/or cool temperatures.
Electrical Specifications
Range style
Total
k.W.
Three Phase
Single Phase
208 Volt
240 Volt
480 Volt
208 V 240 V
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
Range Top Only
15
41.7
41.7
41.7
36.1 36.1
36.1
18.1
18.1 18.1
72.1
62.5
W / Conv. Oven
21.6
48.3
69.2
62.5
41.9 59.9
54.1
20.5
29.5 27.1
103.8
90
W / Bake Oven
21
45.8
66.7
62.5
39.7 57.8
54.1
19.9
28.9 27.1
101
87.5
3
1,5 2,4,6
TO RANGE
TOP
TO
OVEN
Three Phase with Oven
L1 L2
L3
4,5
1,3
6,2
TERMINAL BLOCK
RANGE TOP ONLY
Three Phase w/o Oven
L1 L2
L3
2,4,6
1,3,5
TO RANGE
TOP
TO
OVEN
Single Phase with Oven
L1 L2
L3
IL1412a