6.2 Basic setting
The TSG default parameters are pre-configured. Normally the default parameter’s settings do not need to be
changed.
6.3 User setting - P parameters
P parameters are used to set drive values quickly.
When you press the jog wheel, the TSG switches to the Parameter menu. The first menu item to appear is
P0. Turning the jog wheel clockwise (c.w.) increases the parameter menu, while turning it anticlockwise
(c.c.w.) reduces the menu.
To see the values of the relevant parameter, press the jog wheel briefly.
Table 2: P parameters
Function
Note
Default
Min Max Factor
Unit
P0
Return to special functions
P1
Manual mode
(see also Chapter 5.4 Manual mode / manual travel / page 15)
P2
Max. Open speed
50
01
80
0.01
[m/s]
P3 Max.
Close
speed
30
01 80 0.01
[m/s]
P4
Locking and unlocking speed
Creep speed shortly before
Door Closed end position
15 01
P3
0.01
[m/s]
P5
Acceleration and braking in
Open direction
07
01
50
0.1
[m/s²]
P6
Acceleration and braking in
Close direction
07
01
50
0.1
[m/s²]
P7
Locking and unlocking distance
Creep distance shortly
before Door Closed end
position
03 00
99
1 [cm]
P8
Limit value "Obstructed detection"
in Close direction
Obstruction force
4.0
0.1
9.9
1
P9
Activation of programmed travel
(see also chapter 5.3 Self_Learn Procedure / page 14)
CC Exit the menu.
Select CC and press the jog wheel to leave the P-parameter menu.
After the value is set, press the jog wheel to save the displayed value and exit parameters.
When you select
and press the jog wheel, the menu skips one step back.
NOTE:
All parameters that have been changed are permanently saved in the memory, where they
will be available even after a power failure.