Unit
hb Closing and opening time of the
skate
Only with additional board that
can be optionally fitted and
hA=01 or hA=03
0.1 0.7 3.0
[seconds]
hC Pause between opening of the
skate and opening of the door
Only with additional board that
can be optionally fitted and
hA=01 or hA=03
0.1 0.7 3.0
[seconds]
hd Torque to find the end position in
Close direction while teaching
0.1
5.0
9.9
[A]
hE Torque to find the end position in
Open direction while teaching
and reference
0.1
5.0
9.9
[A]
hF Suppression of Blockage
detection in the last 0mm to
50mm(maximum) in the close
direction.
The maximum setting of 50mm is
a combination of parameters bb +
hF
for example: if bb = 10mm then
hF -> = 40mm (Max)
Warning:
in this distance the
blockage detection is disabled.
00 00 50
[mm]
CC Exit the menu.
Select CC and press the jog wheel to leave the h-parameter menu and
return to c.o.