10 Troubleshooting
In case of a fault, the TSG door control device will indicate a fault on the display (see also Table 6: E
parameters / page 25).
Table 9: E Errors/faults - error elimination
Fault/Error Function
Meaning
Cause
Remedy
E0
Door travel not
limited.
The travel of the door
is not limited or no end
position found.
End position in open
direction is not
defined.
Check the mechanic of
the door.
End position in close
direction is not
defined.
Check the mechanic of
the door.
Toothed belt failed.
Check the toothed
belt.
E1
Door travel path
locked
The door does not
move.
This error occurs
outside the range of
"Obstructed detection“!
Within the range of
"Obstructed detection",
the "Obstructed output"
is set and "bl" appears
in the display.
The current door travel
distance is less than
the programmed door
width.
(see parameter set
"b.l".)
This error is reset after
15 seconds. During
this time, the door
drive does not respond
to input drive signals.
If input drive signals
are present, the door
drive starts with a
reference movement at
slow speed.
The door lock has not
been unlocked.
Check the door
mechanics.
There is an
obstruction in the
door.
Check the door travel
path. Remove the
obstruction.
The initial
measurement
movement of the door
is incorrect or has not
been performed.
Start the initial
measurement
movement (see P9)
The buffer-type stops
for the "Closed
position“ or "Opened
position" are missing
or have been
incorrectly adjusted.
Start the initial
measurement
movement (see P9)
The toothed belt
tension has been
changed.
Start the initial
measurement
movement (see P9)
E2
EEPROM errors
If an EEPROM error
occurs, the drive is
brought to a stop.
Hardware may be
faulty
Replace TSG
electronics unit.