12.2 Intermediate positions in the travel zone
Three different intermediate positions can be stored and approached through separate inputs. To do this, the
TSG expansion board (optionally available) must be installed on the TSG electronics unit. For additional
details on settings and for this function and starting it up, see manual:
1.20.91550 Documentation for TSG expansion board.
12.3 Emergency power supply
The TSG electronics unit is optionally available with an emergency power supply. The emergency power
supply consists of an additional electronic part on the TSG board and two batteries (NiMh).
In case of main power off (230[VAC] off) the door can be opened or closed as long as the batteries provide
enough power. The number of trips and the speed depends on the weight and the smoothness of the door to
be traversed. Normally, a reduced speed can be expected. When the mains power voltage is present in the
TSG electronics unit again, the system switches back to normal mode.
If the two batteries connected correctly, identified by the TSG electronics, the system is ok and the main
power is on the point of the right 7-segment display flashes in seconds when the batteries are charged. The
two batteries are fully charged, the TSG electronic switches to maintenance mode and the point of the right
7-segment display lit.
Is the main power off and the batteries are connected the point of the right 7-segment display flashes fast
(about 0.5 seconds intervals). If the batteries are exhausted, the TSG is switched off.
CAUTION:
No voltage is on X1.6 when the TSG is in emergency power supply mode!