3 Range of service applications for the TSG
The TSG door control device is a door drive for car and shaft doors on elevators. The manufacturer assumes
no liability for applications that fall outside the defined area of usage. The speed and acceleration settings
can be adjusted. The door opening width is determined by a measurement process.
The range of service applications for the TSG door control unit is divided into the following groups:
1. TSG 200:
up to about 180 - 200 [kg] door panel weight
2. TSG 400:
up to about 350 - 400 [kg] door panel weight
NOTE:
When calculating the weight of the door panel, the weights of the car and shaft door must be
included. All shaft doors have closing weights or closing springs in accordance with EN81 so
that the doors will close automatically if there is no car door behind the shaft door. These
weights or springs reduce the maximum door panel weight.
As a rough estimate: 1 [kg] closing weight corresponds to about 30 - 40 [kg] door panel weight.
The TSG 200 is sufficient for doors with access width up to at least about 900 [mm] (no glass doors, normal
doors without additional covering). The TSG 400 can be used with a travel path up to about 20,000 [mm] if
the weights of the door panels do not exceed 350 - 400 [kg].
CAUTION:
Gear reductions or increases on the TSG toothed belt change kinetic and static forces! When
this happens, the door width is no longer valid.