background image

TROUBLESHOOTING:

1. Power is off.

1. Make sure power supply is on.

Lights will not turn on.

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

2. Faulty switch.

2. Test or replace switch.

3. Faulty wire connection.

3. Check wiring.

Fuse blows or circuit 
breaker trips when light is 
turned on

1. Crossed wires or power wire is 
grounding out.

1. Check wire connections.

• To clean the fixture disconnect power to the fixture by turning off the circuit breaker or by

PRODUCT MAINTENANCE:

turned on.

• To clean the fixture, disconnect power to the fixture by turning off the circuit breaker or by

removing the fuse at the fuse box. Wait a few minutes for the fixture to cool down. Use a
dry or slightly dampened clean cloth (use clean water, never a solvent) to wipe the glass
and surface of the fixture.

• Do not use any cleaners with chemicals, solvents or harsh abrasives. If necessary, use a

mild soap to clean off any dirt or stains.

ONE YEAR LIMITED WARRANTY

Langport Lighting

®

warrants this product to be free from defects in material and

gp

g

g

p

workmanship for one year from the original date of purchase by the consumer.

This

warranty is limited to the counter replacement at the time of purchase, with the original
purchase receipt.

Langport Lighting

®

will not be liable for the loss or damage of any

kind, incidental or consequential damages of any kind, whether based on warranty contract
or negligence, and arising in connection with the sale, use or repair of the product claimed
to be defective

Some states do not allow the exclusion or limitation of incidental or

to be defective.

Some states do not allow the exclusion or limitation of incidental or

consequential damages so the above limitation may not apply to you. This warranty gives
you specific legal rights and you may also have other rights, which vary from state to state.
Misuse, accident, improper installation or maintenance will also void the warranty.

Page 11

Summary of Contents for LPT-1006

Page 1: ...INSTRUCTIONS FOR OUTDOOR HANGING LANTERN MODEL LPT 1006 Page 1 ...

Page 2: ... Parts Please contact our Customer Service Team at 1 877 698 2157 Customer service hours are Monday through Friday between 8 AM and 5 PM Pacific time You may also contact us via fax at 1 310 886 3719 or e mail at I f L tli hti GENERAL Info Langportlighting com KEEP this instruction manual KEEP your receipt for proof of purchase TOOLS AND ITEMS REQUIRED FOR INSTALLATION AND TOOLS AND ITEMS REQUIRED...

Page 3: ...box and make sure that parts are are not missing by referencing illustrations below Parts are not to scale MOUNTING BRACKET MOUNTING SCREWS 2 NIPPLE HEX NUTS 2 MAIN FIXTURE BODY SCREW COLLAR LOOP CANOPY WIRE NUTS 3 THREADED RING CHAIN 3 FEET Page 3 ...

Page 4: ...EGIN The OUTLET BOX described in the following section is not provided To install this fixture a standard OUTLET BOX needs to be pre installed at the selected mounting location Power supply wires need to be run into the OUTLET BOX extending approximately 6 from its opening If an OUTLET BOX does not exist contact a 1 DISCONNECT POWER AT THE CIRCUIT BREAKER 2 U i t i f li th h i li k t th d f th CHA...

Page 5: ...d the two HEX NUTS onto the NIPPLE to its approximate midpoint Thread the NIPPLE in throught the center hole of the MOUNTING BRACKET approximately 1 3 of the way Do not tighten the HEX NUTS FIG 3 y g Pull the SUPPLY WIRES and the SUPPLY GROUND WIRE out from the OUTLET BOX Attach the MOUNTING BRACKET to the OUTLET BOX by feeding the MOUNTING SCREWS through the slots of the MOUNTING BRACKET and thre...

Page 6: ...f the SCREW COLLAR LOOP aligns with the bottom surface of the CANOPY OUTLET BOX If not turn the SCREW COLLAR LOOP until its midpoint aligns with the CANOPY FIG 4 FIG 4 CANOPY SCREW COLLAR LOOP 8 Remove the CANOPY and tighten the top HEX NUT against the MOUNTING Page 6 8 Remove the CANOPY and tighten the top HEX NUT against the MOUNTING BRACKET FIG 3 Slide the THREADED RING onto the CHAIN followed ...

Page 7: ... top link of the CHAIN Raise the OPENED CHAIN LINK along with the CHAIN and the MAIN FIXTURE BODY up to the g p ceiling and hook it onto the SCREW COLLAR LOOP Using pliers close the OPENED CHAIN LINK FIG 6 SCREW COLLAR LOOP OPENED CHAIN LINK FIG 6 CHAIN THREADED RING CANOPY CORD FIXTURE GROUND WIRE THREADED RING TOP LOOP Page 7 ...

Page 8: ... CORD and FIXTURE GROUND WIRE leaving approximately 6 y g pp y extending from the OUTLET BOX Split apart the CORD separating the RIBBED WIRE and the SMOOTH WIRE Strip off 3 8 of insulation from each wire Loop the FIXTURE GROUND WIRE around the GROUND SCREW Tighten the GROUND SCREW against the MOUNTING BRACKET Make the following wire connections FIG 9 WHITE NEUTRAL SUPPLY WIRE to RIBBED FIXTURE WIR...

Page 9: ...oward the OUTLET BOX up against the ceiling surface Slide the THREADED RING up the CHAIN and thread it onto the SCREW WHITE NEUTRAL SUPPLY WRE GROUND WRE FIG 9 surface Slide the THREADED RING up the CHAIN and thread it onto the SCREW COLLAR LOOP to secure the CANOPY flush against the ceiling surface FIG 10 OUTLET BOX CANOPY THREADED RING SCREW Page 9 FIG 10 SCREW COLLAR LOOP ...

Page 10: ...SBCFL Self Ballasted Compact Fluorescent Lamp not provided into the socket of the MAIN FIXTURE BODY Do not exceed a 100 Watt incandescent LIGHT BULB or a 26 Watt SBCFL FIG 11 MAIN FIXTURE BOCY Fig 11 LIGHT BULB Page 10 15 RESTORE POWER AT THE CIRCUIT BREAKER Turn on the wall switch ...

Page 11: ...ry use a mild soap to clean off any dirt or stains ONE YEAR LIMITED WARRANTY Langport Lighting warrants this product to be free from defects in material and gp g g p workmanship for one year from the original date of purchase by the consumer This warranty is limited to the counter replacement at the time of purchase with the original purchase receipt Langport Lighting will not be liable for the lo...

Page 12: ...Page 12 ...

Reviews: