3/16/2020
www.reddevilsnowblowers.com | Red Devil Snow Blowers
Page | 4
Red Devil Snow Blowers is a registered trademark of Lankota Group.
Chute Installation
Figure 3
1.
Place and center the chute on the impeller housing flange as shown in Figure 2.
2.
Slide one of the chute gears (RED89SH
-
0005) underneath the chute so that it engages with the hydraulic rotation motor as shown in Figure 3
3.
Place one chute gear clamp (RED89H
-
0004) and two chute clamp shims (RED89SH1011) under the chute gear, align all holes and attach using the
3/8”
carriage bolts and
3/8”
lock nuts (See Figure 4). Verify that the chute gear is clamped directly to the chute and not the impeller housing flange.
4.
Repeat steps 2 & 3 on the other side of the chute.
5.
Grease the flange with the zerk installed on the bottom side of chimney flange. Rotate chute as you grease to ensure even grease distribution.
6.
Tighten or loosen nuts after greasing to maintain a firm grip that will rotate easily.
7.
Slide motor and gear assembly forward to make a tight fit with the chute gear and tighten bolts attaching the motor to the housing as shown in Figure 5.
Figure 2
Figure 5
Figure 4