background image

LPF30F_UG_ENB01W

www.lanpro.com

User Guide for SC Field Installable

LP-F30F Connectors (0.9mm type)

Step 1:

  

Insert the boot 

into the buffer.

Step 3:

  

Strip off the 

buffer and 250 um

coating till 

Mark 1

,

and keep 125um fiber.

Step 5:

  

Press the LP-F30F tool and then insert the 125 um fiber to reach the

innermost until the buffer make a curve.  Then release the tool and check if this 

buffer is tight.

Step 7:

  

Release the tape to take out the LP-F30F connector, and done.

Step 2:

  

Make marks 

on buffer according 

to the length chart.  

(

Mark 1: 

 The starting 

point to strip the buffer.  

Mark 2:

  Check point)

Step 4:

 

 Follow the 

LP-F30TOOL FIBEr 

CUTTEr MaNUaL

to cut the fiber

Step 6:

  

Move the boot 

toward to the stopper.

MARK 2

MARK 1

Reviews: