background image

14

15

5.1 Power Options

The pump may be operated using the following power supply modes:

AC Adapter

1. 

Connect the AC adapter to the power 

receptacle located on the right side 
of the pump. Plug the AC adapter 
into an available electrical outlet. 

2. 

Electrical safety can only be achieved 

when the breast pump is connected 
to the AC power adapter supplied 
with the product. (See “Technical 
Data” section, page 23)

AA Alkaline Batteries (not included)

1.

  Make sure the batteries are inserted 

correctly according to the polarity (+) 
and (-) as indicated. 

2.

  Close the compartment by gently 

pressing the cover until it snaps 
into place.

• 

Remove batteries if pump is not in use 
for a long period of time. 

• 

Dispose of batteries according to 
regulations for environmental protection and recycling. 

• 

Replace batteries as a simultaneous set. Do not mix old and  
new batteries. 

• 

Do not mix alkaline and standard (carbon-zinc) batteries. 

• 

If batteries are in the pump, but AC adapter is in use, the pump will use the 
adapter to power the pump, not the batteries.

For the most economical use, we recommend using your pump with the AC 
adapter provided. Your AC adapter is a universal AC plug adapter type and can 
be used with 100 Vac to 240 Vac systems with 50Hz and 60Hz mains.

3. 

Insert pump connector into 

opening on left side of pump.

2. 

Secure other end of 600mm 

tubing firmly to the pump 
connector.

1. 

Secure one end of 600mm tubing 

to tubing Y connector.

4.2 Connecting the Breastmilk Expression Set

Once Breastmilk Expression Set is assembled, connect to pump base:

4.3 Connecting for Single Pumping

1. 

Remove one of the 300mm  

tubing from the tubing Y 
connector.

2. 

Secure plug into open outlet of  

tubing Y connector.

5. USING THE LANSINOH® SMARTPUMP 2.0  

    DOUBLE ELECTRIC BREAST PUMP

Summary of Contents for SM ARTPUMP 2.0

Page 1: ...1 INSTRUCTIONS FOR USE S M A R T P U M P 2 0 D o u b l e El ectr i c Breast P ump...

Page 2: ...ions should always be maintained To reduce the risk of burns electrocution fire or injury to persons This product should never be left unattended when plugged in Close supervision is necessary when th...

Page 3: ...24 27 PLEASE DO NOT RETURN THIS PUMP TO THE RETAILER Lansinoh s dedicated Customer Service team is here to help If you experience any issues with your Lansinoh Smartpump 2 0 breast pump please call 01...

Page 4: ...ery first time it starts in let down mode suction level 5 When you switch to the expression mode the pump will start in style 2 suction level 3 Adjusting Suction Levels Increase or decrease the suctio...

Page 5: ...eastmilk Expression Set Includes B1 ComfortFit Breast Cushion 25mm 2 53408 B2 ComfortFit Breast Cushion 30 5mm 2 50419 B3 Smartpump 2 0 Breast Cushion Body 2 53454 B4 Smartpump 2 0 Diaphragm 2 53402 B...

Page 6: ...te basin that is used only for cleaning infant feeding items 5 Place pump parts on a clean unused tea towel or paper towel in an area protected from dirt and dust Do not use a tea towel to rub or pat...

Page 7: ...4 Holding the base of the white valve gently secure the valve into the bottom of the breast cushion body 6 Attach end of 300mm tubing to back of diaphragm cap Ensure that tubing is pushed all the way...

Page 8: ...ng Replace batteries as a simultaneous set Do not mix old and new batteries Do not mix alkaline and standard carbon zinc batteries If batteries are in the pump but AC adapter is in use the pump will u...

Page 9: ...pass the pre set two minute let down phase or your milk lets down sooner than two minutes press the let down expression toggle button to move to the expression phase 4 Automatic memory function will s...

Page 10: ...it is not necessary to time your pumping sessions As you get more experienced with pumping you will get a better sense of the time it takes for your body to express your milk using a breast pump If yo...

Page 11: ...alve with one of the spare valves provided with the product 8 BREASTMILK STORAGE GUIDELINES Breastmilk Storage and Thawing Guidelines for Healthy Term Babies Check with your healthcare professional or...

Page 12: ...ble and controlled from keypad Suction vacuum level Minimum 80 mmHg maximum 250 mmHg Cap Teat Collar Bottle Insert the teat into top of the collar NOTE DO NOT MICROWAVE BREASTMILK Microwaving alters t...

Page 13: ...is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect...

Page 14: ...urbances induced by RF fields c d o IEC 61000 4 6 3 V m 0 15 MHz 80 MHz 6 V m in ISM bands between 0 15 MHz and 80 MHz n 80 AM at 1 kHz e 3 V m 0 15 MHz 80 MHz 6 V m in ISM and amatuer radio bands bet...

Page 15: ...DE53260IF0820 2020 Lansinoh Laboratories Inc Alexandria VA USA...

Reviews:

Related manuals for SM ARTPUMP 2.0