background image

 

 

FCC Warning 

 

This  Equipment  has  been  tested  and found to  comply  with  the  limits for a 

Class-A  digital  device,  pursuant  to  Part  15  of  the  FCC  rules.  These  limits 

are designed to provide reasonable protection against harmful interference 

in  a  residential  installation.  This  equipment  generates,  uses,  and  can 

radiate radio frequency energy. It may cause harmful interference to radio 

communications  if  the  equipment  is  not  installed  and  used  in  accordance 

with  the  instructions.  However,  there  is  no guarantee  that  interference  will 

not  occur  in  a  particular  installation.  If  this  equipment  does  cause  harmful 

interference  to  radio  or  television  reception,  which  can  be  determined  by 

turning  the  equipment  off and on,  the  user  is  encouraged  to  try  to  correct 

the interference by one or more of the following measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to 

which the receiver is connected. 

 

Consult the dealer or an experienced radio/TV technician for help. 

 

 

CE Mark Warning 

 

This  is  a  Class-A  product.  In  a  domestic  environment  this  product  may 

cause  radio  interference  in  which  case  the  user  may  be  required  to  take 

adequate measures. 

 

 

 

 

 

 

Summary of Contents for IPES-3424DSFP-2P

Page 1: ...IPES 3424DSFP 2P IES 3424DSFP 2P 24 10 100TX PoE 4 DualSpeed SFP Industrial L2 Switch w ITU G 8032 Ring User Manual Hardware Mar 2022...

Page 2: ...y an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where la...

Page 3: ...consent of Lantech Communications Global Inc Products offered may contain software which is proprietary to Lantech Communications Global Inc The offer or supply of these products and services does no...

Page 4: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Page 5: ...2 3 LED Indicators 7 Chapter 3 Hardware Installation 8 Hardware installation 8 3 1 Rack Mounting 10 3 2 Wiring the Power Inputs 12 3 3 Wiring the Fault Alarm Contact 14 3 4 Cabling 15 3 5 USB Dongle...

Page 6: ...pter 1 Introduction Lantech I P ES 3424DSFP 2P is a high performance L2 managed industrial switch which provides L2 wire speed and advanced security function for network aggregation and backbone deplo...

Page 7: ...re Description In this paragraph it will describe the Industrial switch s hardware spec port cabling information and wiring installation 2 1 Physical Dimension Metal case IP 30 440 W x 325 D x 44 H mm...

Page 8: ...3 IES 3424DSFP 2P...

Page 9: ...t access to hazardous parts e g electrical conductors moving parts and the ingress of solid foreign objects Level Object size protected against Effective against 0 No protection against contact and in...

Page 10: ...est duration 10 minutes Water equivalent to 3 mm rainfall per minute 3 Spraying water Water falling as a spray at any angle up to 60 from the vertical shall have no harmful effect Test duration 5 minu...

Page 11: ...at least 1 m measured at bottom of device and at least 15 cm measured at top of device 8 Immersion beyond 1 m The equipment is suitable for continuous immersion in water under conditions which shall...

Page 12: ...ff Power 1 is inactive PWR2 Green On Power 2 is active Off Power 2 is inactive FAULT Red On Power or port failure Off No failure RJ 45 Link Ack On A network device is detected Blinking The port is tra...

Page 13: ...the Industrial switch in a 19 inch Rack 4 Power on the Industrial switch Please refer to the Wiring the Power Inputs section for knowing the information about how to wire the power The power LED on t...

Page 14: ...9 7 When all connections are set and LED lights all show in normal the installation is complete...

Page 15: ...equipment rack brackets included with the switch Cross head screwdriver not provided Four standard equipment rack screws not provided Perform this procedure to install the switch in a 19 inch equipme...

Page 16: ...11...

Page 17: ...system power input 1 and 2 The power input module 2 is optional part 1 Insert DC power wires into the contacts and for power 1 or and 1 for power 2 2 Tighten the wire clamp screws for preventing the...

Page 18: ...13 NOTE The wire gauge for the terminal block should be in the range between 12 24 AWG...

Page 19: ...e switch will detect the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for w...

Page 20: ...tor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communications The SFP slots supporting Gigabit speed up to 1000Mbps They are used...

Page 21: ...16 Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver LC connector to the transceiver...

Page 22: ...follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Remove LC connector Second push down the metal loop and pull the transceive...

Page 23: ...18 3 5 USB Dongle The USB slot is to backup and restore the setting of switch automatically by any USB dongle It doesn t need any configuration from web browser or other user interface...

Page 24: ...cable which one end is DB9 female connector and the other end is DB9 male connector Attach the end of DB9 female connector to PC or terminal and the other end of DB9 male connector to the console port...

Page 25: ...f the console port Baud Rate 115200 bps Data Bits 8 Parity none Stop Bit 1 Flow control None The settings of communication parameters Having finished the parameter settings click OK When the blank scr...

Page 26: ...21 Console login interface Notice For web based management please refer to our Software Management Manual Please contact support lantechcom tw for more information...

Reviews: