This is the current operational state of the interface.
The 'Link Status' Testing state indicates that no operational packets can be passed.
If 'Admin Status' is Down then 'Link Status' likely will be Down.
If 'Admin Status' is changed to Up, then 'Link Status' should change to Up if the interface is ready to
transmit and receive network traffic.
'Link Status' should change to Dormant if the interface is waiting for external actions (such as a serial line
waiting for an incoming connection);
'Link Status' should remain in the Down state if and only if there is a fault that prevents it from going to the
Up state;
'Link Status' should remain in the NotPresent state if the interface has missing (typically, hardware)
components.
Link Status:
Down
: The ION system interface is not ready to transmit and receive network traffic due a
fault.
1. Review any specific fault and its recommended recovery procedure.
2. Verify the initialization process; see “
Section 2: Installation and System Setup
“ on page
40
.
3. Verify the attempted operation procedure in the related section of this manual.
4. Retry the operation. Wait several minutes for initialization to take place.
5. If the problem persists, contact Technical Support.
Link Status:
Dormant
: The ION system interface is waiting for external actions (such as a serial line
waiting for an incoming connection).
1. Wait several minutes for initialization to take place, and then retry the operation.
2. If the problem persists, contact Technical Support.
Link Status:
NotPresent
: the interface has missing components (typically hardware).
1. Verify the ION system installation; see “
Section 2: Installation and System Setup
“ on page
40
.
2. Wait several minutes for initialization to take place, and then retry the operation.
3. If the problem persists, contact Technical Support.
Link Status:
Testing
:
The ION system interface can not pass operational packets.
1. Verify that diagnostic tests were run properly and completed successfully.
2. Wait several minutes for initialization to take place, and then retry the operation.
3. If the problem persists, contact Technical Support.