5: Commands and Levels
EDS-MD® Wired IoT Device Gateway Command Reference
638
baud rate
<bits per second>
Sets the line speed. <bits per second> = the speed.
Standard speeds include 1200, 2400, 4800, 9600,
19200, and so on.
clear line counters
Sets the serial counters to zero.
clrscrn
Clears the screen.
command mode always
Sets the current line to always be in command
mode.
command mode echo serial string disable
Disables user-defined serial boot string to be
echoed in the CLI.
command mode echo serial string enable
Enables user-defined serial boot string to be echoed
in the CLI.
command mode serial string
Enables user to enter a custom string at boot time to
enter command mode.
command mode serial string
<string>
Sets a string that can be entered at boot time to
enter command mode. <string> = text with possible
binary characters. Within [] use binary decimal up to
255 or hex up to 0xFF. Within {} specify decimal
milliseconds time delay.
command mode signon message
<string>
Sets a sign-on message that is sent from the serial
port when the device boots and when the line is in
command mode. <string> = text with possible binary
characters. Within [] use binary decimal up to 255 or
hex up to 0xFF.
command mode wait time
<milliseconds>
Sets boot-up wait time for command mode serial
string. <milliseconds> = wait time.
configure current settings
Configures line with the current value of settings.
data bits 7
Uses seven bits for data on the line.
data bits 8
Uses eight bits for data on the line.
default baud rate
Restores the default speed of 9600 bits per second.
default data bits
Restores the default of eight data bits.
default flow control
Restores the default of no flow control.
default parity
Restores the default of no parity.
default stop bits
Restores the default of one stop bit.
default threshold
Restores the factory default threshold.
default xoff char
Restores the default xoff character on this line.
default xon char
Restores the default xon character on this line.
exit
Exits to the enable level
flow control hardware
Uses hardware (RTS/CTS) flow control on the line.
flow control none
Does not provide flow control on the line.
flow control software
Uses software (xon/xoff characters) flow control on
the line.
gap timer
<milliseconds>
Sets the gap timer in milliseconds. If some data has
been received, it will be forwarded after this time
since the last character.
kill session
Kills command mode session on the Line
line
<line>
Enters the line level. <line> = number of the line
(serial port) to be configured.
name
<text>
Sets the name for this line.
no clear line counters
Restores the serial counters to the aggregate
values.