5: Commands and Levels
EDS-MD® Wired IoT Device Gateway Command Reference
630
state enable
Enables the line so data can be sent/received.
stop bits 1
Uses one stop bit after data on the line.
stop bits 2
Uses two stop bits after data on the line.
terminal
<line>
Enters the configure-terminal level. <line> = number
of the terminal line (serial port) to be configured.
terminal network
Enters the configure-terminal level for the network.
threshold
<bytes>
Sets the threshold in bytes. After this many bytes
are received, they are forwarded without delay.
tunnel
<line>
Enters the tunnel level. <line> = number of the
tunnel line (serial port) to be configured.
write
Stores the current configuration in permanent
memory.
xoff char
<control>
Sets the xoff character for use with software flow
control on this line. The character may be input as
text, control, decimal, or hex. A control character
has the form <control>C. A decimal value character
has the form \99. A hex value character has the
form 0xFF.
xon char
<control>
Sets the xon character for use with software flow
control on this line. The character may be input as
text, control, decimal, or hex. A control character
has the form <control>C. A decimal value character
has the form \99. A hex value character has the
form 0xFF.
line 3 (config-mach10-line:3) level commands
clrscrn
Clears the screen.
command delimiter
<text>
Sets the command delimiter.
content check interval
<hours>
Sets the firmware and configuration check interval.
default command delimiter
Restores the command delimiter.
default content check interval
Restores the default firmware and configuration
check interval.
default status update interval
Restores the default status update interval.
exit
Exits to the config-mach10 level.
line
<number>
Change to line configuration level.
no project tag
Restores the default Project Tag.
project tag
<text>
Sets the Project Tag.
show
Displays the current configuration.
show history
Displays the last 20 commands entered during the
current CLI session.
state disable
Disables command processing on line.
state enable
Enables command processing on line.
status update interval
<minutes>
Sets the status update interval.
write
Stores the current configuration in permanent
memory.
line 4 (line:4) level commands
auto show statistics
Continuously displays line statistics.
baud rate
<bits per second>
Sets the line speed. <bits per second> = the speed.
Standard speeds include 1200, 2400, 4800, 9600,
19200, and so on.