5: Commands and Levels
EDS-MD® Wired IoT Device Gateway Command Reference
647
default command delimiter
Restores the command delimiter.
default content check interval
Restores the default firmware and configuration
check interval.
default status update interval
Restores the default status update interval.
exit
Exits to the config-mach10 level.
line
<number>
Change to line configuration level.
no project tag
Restores the default Project Tag.
project tag
<text>
Sets the Project Tag.
show
Displays the current configuration.
show history
Displays the last 20 commands entered during the
current CLI session.
state disable
Disables command processing on line.
state enable
Enables command processing on line.
status update interval
<minutes>
Sets the status update interval.
write
Stores the current configuration in permanent
memory.
line 11 (line:11) level commands
auto show statistics
Continuously displays line statistics.
baud rate
<bits per second>
Sets the line speed. <bits per second> = the speed.
Standard speeds include 1200, 2400, 4800, 9600,
19200, and so on.
clear line counters
Sets the serial counters to zero.
clrscrn
Clears the screen.
command mode always
Sets the current line to always be in command
mode.
command mode echo serial string disable
Disables user-defined serial boot string to be
echoed in the CLI.
command mode echo serial string enable
Enables user-defined serial boot string to be echoed
in the CLI.
command mode serial string
Enables user to enter a custom string at boot time to
enter command mode.
command mode serial string
<string>
Sets a string that can be entered at boot time to
enter command mode. <string> = text with possible
binary characters. Within [] use binary decimal up to
255 or hex up to 0xFF. Within {} specify decimal
milliseconds time delay.
command mode signon message
<string>
Sets a sign-on message that is sent from the serial
port when the device boots and when the line is in
command mode. <string> = text with possible binary
characters. Within [] use binary decimal up to 255 or
hex up to 0xFF.
command mode wait time
<milliseconds>
Sets boot-up wait time for command mode serial
string. <milliseconds> = wait time.
configure current settings
Configures line with the current value of settings.
data bits 7
Uses seven bits for data on the line.
data bits 8
Uses eight bits for data on the line.
default baud rate
Restores the default speed of 9600 bits per second.
default data bits
Restores the default of eight data bits.
default flow control
Restores the default of no flow control.
default parity
Restores the default of no parity.