5: Commands and Levels
EDS-MD® Wired IoT Device Gateway Command Reference
80
protocol telnet
Uses Telnet protocol (with IAC) for accept mode
tunneling.
show
Displays the current configuration.
show history
Displays the last 20 commands entered during the
current CLI session.
show status
Displays tunnel accept status.
start character
<control>
Sets the accept mode start character. The character
may be input as text, control, decimal, or hex. A
control character has the form <control>C. A
decimal value character has the form \99. A hex
value character has the form 0xFF.
tcp keep alive idle time
<milliseconds>
Sets the TCP keep alive idle time. This is the initial
keep alive timeout. <milliseconds> = timer value, in
milliseconds.
tcp keep alive interval
<milliseconds>
Enables TCP keep alive for accept mode tunneling
and sets the value for timeouts subsequent to the
initial timeout. <milliseconds> = timer value, in
milliseconds.
tcp keep alive probes
<number>
Sets the number of TCP keep alive probes.
<number> = number of TCP keep alive probes.
write
Stores the current configuration in permanent
memory.
accept (tunnel-accept:5) level commands
accept mode always
Enables the tunneling server to always accept
tunneling connections.
accept mode any character
Enables the tunneling server to accept tunneling
connections only when a character is received
through the corresponding line (serial port).
accept mode disable
Disables accept mode tunneling.
accept mode modem control asserted
Enables the tunneling server to accept tunneling
connections when the modem control pin is
asserted.
accept mode modem emulation
Enables modem emulation for accept mode
tunneling.
accept mode start character
Enables accept mode tunneling when the
configured start character is received on the line.
aes decrypt key
<hexadecimal>
Sets the accept tunnel AES decrypt key with up to
16 bytes. Each byte is represented by two adjacent
hex digits. Bytes may run together or be separated
by optional punctuation: 123ABC "12 3A BC"
12,3A,BC 12.3a.bc 12:3a:bc Note that quotes must
enclose the value if it contains spaces.
aes decrypt key text
<text>
Sets the accept tunnel AES decrypt key with up to
16 bytes. Each byte is represented by a single
character. Note that quotes must enclose the value
if it contains spaces.
aes encrypt key
<hexadecimal>
Sets the accept tunnel AES encrypt key with up to
16 bytes. Each byte is represented by two adjacent
hex digits. Bytes may run together or be separated
by optional punctuation: 123ABC "12 3A BC"
12,3A,BC 12.3a.bc 12:3a:bc Note that quotes must
enclose the value if it contains spaces.