4: Configuration Using XML
EDS1100/2100 Command Reference
26
line
(Attribute of
“instance” is
a number.)
name
interface
rs232, rs485 half-
duplex, rs485 full-
duplex
Default:
termination
enable, disable
Default: disable
state
enable, disable
Default: depends
on instance
protocol
none, modbus rtu,
modbus ascii,
tunnel, ppp, lpd,
lpd or tunnel
Default:
baud rate
Default: 9600 bits
per second
parity
even, none, odd
Default: none
data bits
7, 8
Default: 8
stop bits
1, 2
Default: 1
flow control
none, hardware,
software
Default: none
xon char
Accepts a control
character, for
example,
<control>
A represents
control-A Default:
<control>Q
xoff char
Accepts a control
character, for
example,
<control>
A represents
control-A Default:
<control>S
gap timer
<None>,
...
Default: <None>
threshold
Default: 56 bytes
lpd
(Attribute of
“instance” is
a number.)
banner
enable, disable
Default: enable
binary
enable, disable
Default: disable
soj
enable, disable
Default: disable
eoj
enable, disable
Default: disable
formfeed
enable, disable
Default: disable
convert
newline
enable, disable
Default: disable
soj text
eoj text
queue
name
Group
Name
Group Item Value Name
Value Options
Addition
Information