8: Line and Tunnel Settings
EDS1100/2100 Device Server User Guide
60
5. Click
Submit.
The host is configured. A second host appears underneath the newly
configured host.
6. Repeat these steps to configure additional hosts as necessary. EDS1100/2100 supports
configuration of up to sixteen hosts.
Reconnect Timer
Enter the reconnect time in milliseconds. The device attempts to reconnect after
this amount of time after failing a connection or exiting an existing connection.
This behavior depends upon the Disconnect Mode.
Note:
When you configure
Tunnel - Connect Mode
, you can specify a number of
milliseconds to attempt to reconnect after a dropped connection has
occurred. The default is 1500 milliseconds.
The
Reconnect Timer
only applies if a
Disconnect Mode
is configured.
With a
Disconnect Mode
set, the device server maintains a connection
until the disconnect mode condition is met (at which time the device server
closes the connection). If the tunnel is dropped due to conditions beyond
the device server, the device server attempts to re-establish a failed
connection when the specified reconnect interval reaches its limit.
Any network-side disconnect is considered an error and a reconnect is
attempted without regard to the
Connect Mode
settings. Simultaneous
Connect Mode
connections require some
Disconnect Mode
configurations or the connections will never terminate. See
Connect Mode for a specific tunnel: on page 58
for more information about
the parameters.
If
Disconnect Mode
is disabled and the network connection is dropped,
then the re-establishment of a tunnel connection is governed by the
configured
Connect Mode
settings.
Flush Serial Data
Select whether to flush the serial line when a connection is made. Choices are:
Enabled
= flush the serial line when a connection is made.
Disabled
= do not flush the serial line. (default)
Block Serial
Select
Enabled
to block (not tunnel) serial data transmitted to the device. This is
a debugging tool that causes serial data sent to the device to be ignored.
Block Network
Select
Enabled
to block (not tunnel) network data transmitted to the device. This
is a debugging tool that causes network data sent to the device to be ignored.
Email on Connect
Select whether the device sends an email when a connection is made. Select
None if you do not want to send an email. Otherwise, select the Email profile to
use.
Email on Disconnect
Select whether the device sends an email when a connection is closed. Select
None if you do not want to send an email. Otherwise, select the Email profile to
use.
Tunnel – Connect Mode
Settings (continued)
Description