10: Device Ports
EMG™ Edge Management Gateway User Guide
221
4. Click the right
arrow to add the host. The host displays in the Hosts box.
5. Repeat steps 3-4 to add more hosts to the host list.
6. Click the
Clear Host Parameters
button to clear fields before adding the next host.
7. You have the following options:
-
To remove a host from the host list, select the host in the Hosts box and click the
left arrow.
-
To give the host a higher precedence, select the host in the Hosts box and click the
up
arrow.
-
To give the host a lower precedence, select the host in the Hosts box and click the
down arrow.
8. Click the
Add Host List
button. After the process completes, a confirmation message is
displayed on the page.
Protocol
Protocol for connecting to the host (TCP, SSH, or Telnet).
Port
Port on the host to connect to.
Escape Sequence
The escape character used to get the attention of the SSH or Telnet client. It is
optional, and if not specified, Telnet and SSH use their default escape character.
For Telnet, the escape character is either a single character or a two-character
sequence consisting of '^' followed by one character. If the second character is '?',
the DEL character is selected. Otherwise, the second character is converted to a
control character and used as the escape character.
For SSH, the escape character is a single character.
Note:
When the Device Port Esc Sequence/ViewLog/PowerMenu Escape
Sequence is configured, the following escape sequence precedent behavior can be
expected: 1) Escape 2) PowerMenu 3) ViewLogs
A clear/restart of the remaining escape events occurs when there is a match in any
configured sequence. All the sequences should have unique sequence defined and
user should avoid overlapping sequence strings. When detecting key sequences,
after receiving the first character(s) of a sequence, the EMG will wait 3 or more
seconds for the remaining characters, before timing out and sending all characters
to the device. For example, if the Escape Sequence is ABCD, and the user types
"AB", the EMG will wait at least 3 seconds for the next character ("C") before timing
out and sending the "AB" characters to the device.
Summary of Contents for EMG 7500
Page 100: ...7 Networking EMG Edge Management Gateway User Guide 100 Figure 7 5 Network Wireless Settings ...
Page 353: ...15 Maintenance EMG Edge Management Gateway User Guide 353 Figure 15 12 About EMG ...
Page 474: ...EMG Edge Management Gateway User Guide 474 Figure E 3 EU Declaration of Conformity ...
Page 475: ...EMG Edge Management Gateway User Guide 475 Figure E 4 EU Declaration of Conformity continued ...