admin firmware bootlimit
Syntax
admin firmware bootlimit <3-20>
Description
Configures bootlimit parameters that control how many times the EMG will fail to boot before
switching to the alternate boot bank. After the EMG fails to boot 2 times Boot limit (so it has
attempted to boot Boot Limit times on each bank), the EMG will go into advanced recovery mode,
which may require support from Technical Support to resolve so that the EMG can be booted
again. Default is 3 boots, range is 3 - 20.
admin firmware bootdelay
Syntax
admin firmware bootdelay <3-1800>
Description
Configures bootcount parameters that control how seconds the bootloader pauses before booting
the EMG. The default is 3 seconds and the range is between 3 and 1800 seconds.
admin firmware highrestimers
Syntax
admin firmware highrestimers <enable|disable>
Description
Enables high resolution timers required for Performance Monitoring or disables high resolution
timers (the default). Changing this setting requires a reboot in order for the change to take effect.
admin firmware watchdog
Syntax
admin firmware watchdog <disable|180-1800 seconds>
Description
Configures how long the EMG waits for boot completion before forcing a reboot.
admin firmware show
Syntax