Updating Software
K - 9
The path and filename are case-sensitive and must be enclosed by quotation marks. When
attempting to boot across an IP router, you must configure the router to proxy-ARP for the Server,
or use the bootgateway feature. For more information, see Set/Define Bootgateway in the
Commands
chapter of the
Print Server Reference Manual
on CD-ROM.
K.4.4 MOP
Copy the EPS.SYS file to the MOM$LOAD directory. The EPS.SYS filename is the only
parameter that the Server needs to reload via MOP. Make sure the service characteristic is enabled
on the host's Ethernet circuit, and then reload the server using the
Initialize Reload
command.
NOTE:
If an error message is displayed indicating an invalid record size on the
VAX console, the EPS.SYS file was not transferred in binary mode.