Web-Manager Configuration
WiBox2100E User Guide
39
Mode. The unit will not accept a data connection from a
remote device when the hostlist option is enabled.
LED
Select
Blink
for the status LEDs to blink upon connection or
None
for no LED output. The default setting is
Blink
.
Disconnect Mode
On Mdm_Ctrl_In Drop
Set to
Yes
for the network connection to or from the serial port
to drop when
modem_control_in
transitions from a high state
to a low state. The default setting is
No
.
Hard Disconnect
When this parameter is set to
Yes
, the TCP connection closes
even if the remote site does not acknowledge the disconnect
request.
With EOT
Select
Yes
to drop the connection when
Ctrl+D
or Hex 04 is
detected. Both
Telnet mode
and
Disconnect with EOT
must
be enabled for
Disconnect with EOT
to function properly.
Ctrl+D
is only detected going from the serial port to the
network. The default setting is
No
.
Inactivity Timeout
Use this parameter to set an inactivity timeout. The unit drops
the connection if there is no activity on the serial line before
the set time expires. Enter time in the format mm:ss, where m
is the number of minutes and s is the number of seconds. To
disable the inactivity timeout, enter
00:00
.
3. When you are finished, click the
OK
button.
4. On the main menu, click
Apply Settings
.
Connection Settings - UDP
To configure a channel’s UDP settings
:
1. From the main menu, click
Connection
for either Channel 1 or Channel 2 to
display the Connection Settings page for the selected channel.
Connect Protocol
Protocol
Select
UDP
from the pull-down menu.