Setup Mode: Channel Configuration
WiBox2100E User Guide
62
Table 7-9. Pack Control Options
Option
7 6 5 4 3 2 1 0
Packing Interval
Interval:
12
msec
0
0
Interval:
52
msec
0
1
Interval:
250
msec
1
0
Interval:
5
sec
1
1
Trailing Characters
None
0 0
One
0 1
Two
1 0
Send Characters
2-Byte
Send
Character
Sequence
1
Send
Immediately
After
Send
chars
1
Packing Interval
Packing Interval
defines how long the unit should wait before sending accumulated
characters. This wait period is between successive network segments containing
data. For alternate packing, the default interval is
12
ms.
Trailing Characters
In some applications, CRC, Checksum, or other trailing characters follow the end-of-
sequence character; this option helps to adapt frame transmission to the frame
boundary. The default setting is
00
(none).
Send Characters
If
2-Byte Send Character Sequence
is enabled, the unit interprets the
sendchars as a 2-byte sequence; if this option is not enabled, the unit
interprets them independently. The default setting is
0
(disabled).
If
Send Immediately After Characters
is
not
set, any characters already in
the serial buffer are included in the transmission after a "transmit" condition is
found. If this option is set, the unit sends immediately after recognizing the
transmit condition (sendchar or timeout). The default setting is
0
.
Note:
A transmission might occur if status information needs to be
exchanged or an acknowledgment needs to be sent.
DisConnTime (Inactivity Timeout)
Use this parameter to set an inactivity timeout. The unit drops the connection if there
is no activity on the serial line before the set time expires. Enter time in the format
mm:ss, where m is the number of minutes and s is the number of seconds.