background image

Lantronix 

 

OCA-P181610 Install Guide 

33812 Rev. D 

    

https://www.lantronix.com/

  

Page 

5

 of 

17

 

Compliance 

Consists of UL compliant components. 

Cabinet UL 50/cUL listed File E229365/E207562; NEMA 4X/IP66.  

Vent plug UL/cUL recognized File E330194; approved for use in IP65/67/68 

applications. 

Wire glands UL/cUL recognized File E51579; approved for NEMA 4, 4X, 6 

and 6P applications. 

Ground terminal blocks UL/cUL recognized File E 60425. 

Ordering Information 

SKU 

Description 

OCA-P181610 

18”x16”x10” Outdoor cabinet with vent, (2) DIN rails, (2) ground terminal blocks and 

(1) each low voltage DC positive and negative and AC mains line and neutral/line 

terminal block, plus (1) power, (10) data wire glands, and magnetic door contact 

switch.  

Optional Accessories

 (sold separately) 

OCA-PMK-26 

Universal Pole Mount Kit for 2-6" diameter poles 

Complimentary Products

 (sold separately) 

SISPM1040-384-LRT-C  Managed Hardened Gigabit Ethernet PoE+ Switch with (8) 10/100/1000Base-T 

PoE+ Ports + (4) 100/1000Base-X SFP Slots 

SISPM1040-582-LRT 

Managed Hardened Gigabit Ethernet PoE++ Switch with (8) 10/100/1000Base-T 

PoE++ Ports + (2) 100/1000Base-X SFP Slots 

SISPM1040-362-LRT 

Managed Hardened Gigabit Ethernet PoE+ Switch (4) 10/100/1000Base-T PoE+ 

Ports + (2) 10/100/1000Base-T RJ-45 + (2) 100/1000Base-X SFP Slots

 

PS-DC-DUAL-5624T 

345W Dual Industrial Power Supply, 24VDC + 56VDC 

25104 

Industrial DIN Rail Mounted Power Supply; Input: 85-264 VAC, 124-370 VDC;  

Output: 48~55 VDC, 5.0A, 240 Watts 

25105 

Industrial DIN Rail Mounted Power Supply; Output Voltage 48VDC, 2.5A, 120 Watts.  

Power Input: Voltage Range Switch Selectable: 88~264VAC / 124~370VDC 

25160 

Hardened DIN Rail Mounted Power Supply; Input 90-264 VAC, 127-370 VDC,  

Output: 48 ~ 55 VDC, 10A, 480 Watts 

EDCA-DIO-01 

Enclosure Door Contact Alarm, DIN Rail Mount 

WMB-EDCA 

Enclosure Door Contact Alarm Wall Mount Bracket 

SESPM-4P-FMKIT 

Fiber Management Tray, accommodates (2) splices 

Related Manuals 

  SISPM1040-384-LRT-C and SISPM1040-362-LRT Quick Start Guide, Install Guide, Web User Guide, and 

CLI Reference (33726 – 33729) 

  SISPM1040-582-LRT Quick Start Guide, Install Guide, Web User Guide, and CLI Reference (33754 -  33757) 

  PS-DC-DUAL-5624T Power Supply QSG (33792) and PS-DC-DUAL-5624T Power Supply Install Guide 

(33788) 

  EDCA-DIO-01 Quick Start Guide (33796) and EDCA-DIO-01 Install Guide (33790) 

  OCA-PMK-26 Quick Install Guide, 33820 

  WMB-EDCA: see the EDCA-DIO-01 Install Guide (33790) 

  SESPM-4P-FMKIT Option Install Guide (33775) 

  Power Supplies: 

25104

25105

25160

 and 

PS-DC-DUAL-56xxT

  

 

 

Summary of Contents for OCA-P181610

Page 1: ...OCA P181610 Outdoor Cabinet Assembly 18 x 16 x 10 Polycarbonate Enclosure for Outdoor Switches Install Guide Part Number 33812 Revision D January 2022 ...

Page 2: ...ansition com Sales Offices For a current list of our domestic and international sales offices go to the Lantronix web site at www lantronix com about contact Disclaimer All information contained herein is provided AS IS Lantronix undertakes no obligation to update the information in this publication Lantronix does not make and specifically disclaims all warranties of any kind express implied or ot...

Page 3: ...ance 6 Base Cabinet Compliance 6 Components 6 Dimensions 7 Product Views 8 Install Procedures 9 Ground Terminal Blocks Together 9 Cabinet Mounting 10 If Using an AC Power Source 11 Cutting and Reconnecting AC Power Cord within Enclosure 11 Connecting DC Power within the Enclosure 11 After Installing Cabling 11 Connecting the Magnetic Door Contact Switch 12 Cautions and Warnings 12 Installing the O...

Page 4: ...urges in power to the enclosure Red and black feed through terminal blocks are provided for terminating low voltage DC positive and negative wires within the enclosure Blue and white feed through terminal blocks are provided for AC mains line and neutral line connections End caps are also included for added safety The enclosure includes mounting feet for mounting on a wall or side of a building Op...

Page 5: ...LRT Managed Hardened Gigabit Ethernet PoE Switch 4 10 100 1000Base T PoE Ports 2 10 100 1000Base T RJ 45 2 100 1000Base X SFP Slots PS DC DUAL 5624T 345W Dual Industrial Power Supply 24VDC 56VDC 25104 Industrial DIN Rail Mounted Power Supply Input 85 264 VAC 124 370 VDC Output 48 55 VDC 5 0A 240 Watts 25105 Industrial DIN Rail Mounted Power Supply Output Voltage 48VDC 2 5A 120 Watts Power Input Vo...

Page 6: ...Two Ground Terminal Blocks for 12 26 AWG wire 8kV rated surge protection installed One each Red and Black Terminal Blocks for 12 26 AWG wire 8kV rated surge protection for DC Wires installed One each Blue and White Terminal Blocks for 12 26 AWG wire 8kV rated surge protection for AC Mains Line and Neutral Line Connections installed One Power Wire Gland installed Ten Data Wire Glands accommodate 2 ...

Page 7: ...Lantronix OCA P181610 Install Guide 33812 Rev D https www lantronix com Page 7 of 17 Dimensions ...

Page 8: ...Lantronix OCA P181610 Install Guide 33812 Rev D https www lantronix com Page 8 of 17 Product Views ...

Page 9: ...rovided on both the upper and lower DIN rails For added safety it is recommended that these ground terminal blocks be tied together Note If terminal blocks are moved from original shipping location ensure end caps have been inserted on any open side for safety Note Switch and power supply shown for illustration purposes only sold separately Terminal Block Details ...

Page 10: ...a wall or other flat surface or to a pole If mounting to a flat surface attach the four mounting feet provided to the back of cabinet with screws provided Mount to wall or other flat surface with appropriate screws for the desired mounting surface If mounting to a pole see Installing the OCA PMK 26 Option on page 13 for pole mount instructions ...

Page 11: ...minal blocks 2 Cut the power cord to the desired length 3 Pass the cut end of the AC mains wire from the outside of the enclosure through the strain relief wire gland to the inside of the enclosure 4 Strip the outer sheath of both ends of the power cord to expose enough individual wire length for connecting to the terminal blocks and allowing extra length for drip loops 5 Strip the insulation on e...

Page 12: ...r contact switch Follow the instructions in your Ethernet Switch manual if Ethernet Switch includes alarm input outputs or the optional Enclosure Door Contact Alarm manual for connecting alarm input outputs to the door contact switch Note If making further modifications to this cabinet please note the following Cautions and Warnings Cautions and Warnings Warning Cancer and Reproductive Harm See ht...

Page 13: ...ronix com Page 13 of 17 Installing the OCA PMK 26 Option The OCA PMK 26 is an optional Universal Pole Mount Kit for mounting the OCA P181610 onto 2 6 diameter poles The kit is ordered and packaged separately OCA PMK 26 Option Part List OCA PMK 26 Option Dimensions ...

Page 14: ...Lantronix OCA P181610 Install Guide 33812 Rev D https www lantronix com Page 14 of 17 OCA PMK 26 Option Assembly Note Only one of two Struts shown ...

Page 15: ...all G 2 Hose Clamp 3 1 2 H 2 Hose Clamp 6 1 2 I 2 Hose Clamp 3 OCA PMK 26 Option Install Procedure 1 Attach Band Clamp Brackets E or F x2 to inside of Strut Rails A x2 and secure with Pan Head Screws x Long D Fender Washers C Nylok Nuts E x4 Torque to 32 in lbs Max 2 Attach Strut Rails to the Enclosure mounting bosses and secure with Pan Head Screws x Long D and Fender Washers C x4 Torque to 32 in...

Page 16: ...Lantronix OCA P181610 Install Guide 33812 Rev D https www lantronix com Page 16 of 17 OCA PMK 26 Option Installed Views ...

Page 17: ...vine Center Drive Suite100 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support 1 952 358 3601 1 800 260 1312 or techsupport transition com Sales Offices For a current list of our domestic and international sales offices go to the Lantronix web site at www lantronix com about contact ...

Reviews: