8: Input/Output Ports
PremierWave® XC HSPA+ Intelligent Gateway User Guide
61
Digital Input
contains additional configuration options for
Digital Input 1
and
Digital Input 2
settings:
Table 8-2 Digital Input Settings
To Configure Digital Input Settings
Using Web Manager
To modify digital input information, click
Digital Input
on the menu, select either
Digital Input
1
or
Digital Input 2
, and click the
Configuration
link.
Using the CLI
To enter the digital input command level:
enable -> config -> action -> digital
input 1 state change
To enter the digital input command level:
enable -> config -> action -> digital
input 2 state change
To enter the digital input command level:
enable -> config -> digital inputs ->
digital input <number>
Using XML
Include in your file:
<configgroup name = "action" instance = "digital input
1 state change">
Include in your file:
<configgroup name = "action" instance = "digital input
2 state change">
Include in your file:
<configgroup name="digital input" instance="<number">
Digital Input Settings Description
State
This field is found in the Digital Input Status page. Indicates state of the digital
input.
Title
Fill in Title to customize how the digital input status will appear in the CLI, Web
Manager, and XML status. Leave Title blank for the default title of "Digital Input N",
where N is the digital input number.
Normal State
Select Normal State to
Low
or
High
. When input state anges, Normal State is
used to compare with the input state. If the states are different, an alarm will be
triggered which is configured under "Action" menu.