PremierWave® XC HSPA+ Intelligent Gateway User Guide
67
10: Line and Tunnel Settings
The PremierWave XC HSPA+ intelligent gateway has two tunnels through which you may view
statistics or configure the Accept Mode. The PremierWave XC HSPA+ intelligent gateway contains
two serial lines. All lines use standard RS232/RS485 serial ports. All lines can be configured to
operate in the following modes:
RS232
RS485 Full Duplex (also compatible with RS-422)
RS485 Half Duplex, with and without termination impedance
All serial settings such as Baud Rate, Parity, Data Bits, etc, apply to these lines.
Line Statistics
This page displays the current status and various statistics for the serial line.
Note:
The following section describes the steps to view Line 1 statistics; these steps
apply to other line instances of the device.
Using Web Manager
To view statistics for Line 1, click
Line
in the menu and select
Line 1 ->
Statistics
.
Using the CLI
To view Line statistics:
enable -> line 1, show statistics
Using XML
Include in your file:
<statusgroup name=”line” instance=”1”>
Line Settings
Note:
The following section describes the steps to configure Line 1; these steps apply to
other line instances of the device.
To Configure Line Settings
Using Web Manager
To configure Line 1, click
Line
in the menu and select
Line 1 ->
Configuration
.
Using the CLI
To view Line statistics:
enable -> line 1, show statistics